VALLOX TSK

MAIN PARTS

2

EVERYDAY QUICK GUIDE

VALLOX TSK has been initially adjusted for
normal circumstances in your home. Ventilation
adjustment is needed mainly in the following
circumstances:

• Cooking:

If the ventilation unit is connected to a
cooker hood, boost ventilation during
cooking (the most common way of abating
cooking smokes in blocks of flats). Small
detached houses and terraced houses are
normally equipped with a separate cooker
hood.

• Empty dwelling:

To save energy, ventilation can be adjusted
to the minimum level.

• Sleeping:

Ventilation in a bedroom has to be suffi-
cient throughout the night. The level is cor-
rect when air does not smell fusty when
you enter the room in the morning.

• Washing and drying clothes:

Boost ventilation in washing and drying fa-
cilities during these activities.

• Taking a sauna bath:

Boost ventilation in bathing and washing
facilities in order to ensure that the rooms
get dry as quickly as possible. It is recom-
mended to have boosted ventilation on for
2 to 3 hours after taking a sauna bath.

VALLOX TSK

Safety switch and electric box

Extract air coarse filter G3

Heat recovery cell

Outdoor air fine filter F7

Outdoor air coarse filter G3

Extract air fan (105 or 180 W)

Post-heating radiator, electric (1.0 kW)

or water/liquid radiator ca 1.5 kW (VKL model)

Damper for summer / winter ventilation

Cell antifreeze sensor

Supply air fan (105 or 180 W)

Electrical quick-connect terminal for fans

The unit is available as a right (R) and left (L) hand model.

The figure shows the R model.

1

2

3

4

5

6

7

8

9

10

11

1

2

3

4

5

10

7

6

11

8

9

11

Summary of Contents for TSK Multi 80 MC R

Page 1: ...LLOX CODE 3468 INSTRUCTIONS FOR USE AND MAINTENANCE Supply extract ventilation with heat recovery for dwellings in blocks of flats and terraced houses VALLOX We reserve the right to make changes witho...

Page 2: ...t smell fusty when you enter the room in the morning Washing and drying clothes Boost ventilation in washing and drying fa cilities during these activities Taking a sauna bath Boost ventilation in bat...

Page 3: ...high especially in bedrooms The bathroom and sauna get dry quickly During the heating season the windows and other outer wall structures remain dry Humidity in indoor air is not condensed in the vent...

Page 4: ...en needed as combustion air for a wood heated sauna oven The resident may regulate the power of ventilation air circulation as needed Filtering Outdoor air is filtered before taking it in to the dwell...

Page 5: ...ng for example sauna baths cooking clothes washing or family parties If the user does not know the measured air flows the adjacent table shows approximate extract air flows as well as the total electr...

Page 6: ...ectric box which stops the outdoor air fan in advance The thermostat has been set at the factory to stop the fan when exhaust air temperature goes down to 5 C The fan restarts as soon as exhaust air t...

Page 7: ...eed for ventilation is fairly small and air is good Speed 3 is used when there is a need for boosting for instance in the following situations cooking taking a sauna bath drying clothes use of toilet...

Page 8: ...There are four power ranges available Speed 1 Use during absence When the dwelling is empty ventilation can temporarily be diminished Speeds 2 and 3 These are speeds that are normally used Speed 2 is...

Page 9: ...one when needed preferably at one year intervals depending on local air quality It is recommended to replace filters in autumn This way the filters stay cleaner throughout the winter and can effective...

Page 10: ...pull the fan out of the unit for maintenance When mounting the fan back make sure that it tightly fits the collar 10 Other cleaning During maintenance also check the general cleanliness of the inner s...

Page 11: ...ed fan Follow the same instructions as for the cooker hood connected to the ventilation unit For special instructions see the instructions of the cooker hood NOTE It is absolutely forbidden to flamb u...

Page 12: ...tdoor temperatures check the operation of the antifreeze thermostat The function starts as soon as outdoor temperature goes below 10 C The threshold is not absolute but is dependent on the length of t...