MAINTENANCE INSTRUCTIONS
Location of condensing water
outlet from side
Location of condensing water
outlet from behind
Condensing water
During the heating season, humidity of extract air condenses into
condensing water. Water formation may be abundant in new
buildings or if ventilation is low compared to the humidity build-up
caused by the residents. Condensing water needs to fl ow out from
the ventilation unit without hindrance. In carrying out maintenance,
for instance in autumn before the beginning of the heating season,
make sure that the condensing water outlet (G) in the bottom tank is
not clogged. You can check it by pouring a little water in the tank.
Clean if needed. Do not let water fl ow into electrical devices.
The unit comes with a condensing outlet (in the fi gure) equipped
with an airlock and an outlet without airlock that takes less space. If
you use the outlet without an airlock, you have to mount an airlock
somewhere between the discharge pipes (the accessory bag
contains the parts needed). An airlock guarantees the removal of
condensing water and silencing of any sounds.
G