USING THE COOKER HOOD
The cooker hood has a sliding part that can be pulled
out of the cooker hood. Pull the sliding part out of the
cooker hood for maximal extraction capacity.
Position of the damper
The damper is opened by pressing the damper button
(light turns on). The damper is closed (light turns off) by
pressing the damper button or automatically after one
hour (without a timer or 45-120 min when programmed).
In normal circumstances, the damper must be closed
(the signal light is off), which boosts the extract air flow
from other premises.
The damper must be open
(the signal light is turned on)
when the user wants to increase the extract air flow
from the cooker hood
e.g.
• when the cooker top or the oven is used for
cooking
• when the load in the kitchen is exceptional e.g. due
to the use of strong detergents or the presence of
a large number of people.
Touch the button on the damper to open it and to start
the timer. The damper will close automatically within 60
minutes.
Front panel buttons
The front panel of the cooker hood has two buttons
and two signal lights.
Cooker hood light
Turn the light on or off by pressing the light switch. The
light is dimmable. Adjust the brightness by pressing the
light switch until the brightness is adequate.
Selection button
The selection button is roughly 3 cm to the left from the
damper button. The selection button is not marked on
the front panel.
CAUTION
• Neglecting the cleaning of the grease
filter can cause a fire hazard.
• The outer surfaces of the hood can
become hot when the cooker or the
oven is turned on.
• Flaming is forbidden underneath the
cooker hood.
• Always follow the instructions
provided on adjusting the efficiency of
ventilation.
• Enable a sufficient supply air flow
into the room if the cooker hood
and non-electric devices are used
simultaneously.
The removal of cooking smells can be enhanced by
using the adjustment damper of the hood. Poten-
tial-free contact data and 230 V 4 A supply voltage are
provided of the position of the damper.
When Vallox Delico KTD A is connected to the joint
extraction system of a multi-storey building, a Vallox
Smoke Limiter must also be installed.