External electrical connection
Standard ventilation
The volume flow rate of the air inside the cooker hood is
measured with the damper closed.
Measuring
• The air flow measuring tubes are located behind the cooker
hood light on the right side.
• Connect the differential pressure gauge to the measuring
tube that is marked with a “min.” sticker. The enclosed
figure illustrates the measuring principle.
Adjustment
• Cover the required number of holes in the damper with the
magnetic strip that is delivered with the cooker hood.
• Determine the volume flow rate from the performance
scheme based on the measured pressure and the number
of open holes in the damper.
Boost ventilation
The volume flow rate is measured and adjusted with the damper
open.
Measuring
• The measuring tubes should be connected as specified in
the standard ventilation section.
• The differential pressure gauge is connected to both
measuring tubes. The enclosed figure illustrates the
measuring principle.
• Determine the volume air flow from the performance
scheme based on the measured pressure.
Adjustment
• Cover the required number of holes in the damper with the
magnetic strip that is delivered with the cooker hood.
ALARM
TACHO
GND
PWM
OPT
+ -
DAMP
IN OUT
MODE
IN OUT
F ALARM
RS 485
A B GND
N
L
DAMPER
1 2 3
LIGHT
N L
FAN
N L
IN OUT
PE
EXTRA
POSITION
OF THE FLAP
CONTACT DATA
CONTACT DATA
GUARD FUNCTION
STANDARD VENTILATION
(SETTINGS 3---8)
- damper closed
- available settings
- 2 = 20 holes open/damper
- 3 = 30 holes open/damper
- 4 = 40 holes open/damper
- 5 = 50 holes open/damper
- 6 = 60 holes open/damper
- 7 = 70 holes open/damper
- 8 = 80 holes open/damper
BOOST VENTILATION
(SETTINGS 16---24)
- damper open
- available settings
- 16 = 164 holes open
(2 magnetic strips)
- 20 = 203 holes open
(1 magnetic strip)
- 24 = 242 holes open
(all are open)
A
A
p
A
A
p
Measuring and adjusting performance values
Measuring
standard ventilation
Measuring
boost ventilation
5
6
7
8 9
20
30
40
50
60
10
20
30
40
50
60
70
80
90
200
300
400
100
45
40
35
30
25
45
40
35
30
25
24
20
16
LpA, dB(A)
4 5
3
8
7
2
6
Air flow, dm³/s
Static pressure loss Pa