NERO
04
D MONTAGEANLEITUNG
EN
INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS
CONCEALED UNIT (STEP 1-6):
First, install the flush-mounted unit on the unfinished floor. Proceed as follows:
• Place the flush-mounted unit in the intended location. Now align the concealed unit
horizontally using a spirit level.
• Now connect the entire fitting to the flush-mounted unit for trial purposes. Use a
spirit level here as shown in the sketch. Determine the future alignment of the mixer.
Disconnect it from the flush-mounted unit to continue.
• Now connect the concealed installation unit to the unfinished floor using the three
provided screws.
• Connect the flush-mounted unit to the water supply system of the building via the
1/2 “connections on the sides of the unit. Note the correct connection of hot and
cold water, as shown in the sketch.
• Now attach the protective cap included in the scope of delivery in order to protect
the concealed unit from contamination during installation.
• You may continue the floor work around the concealed installation unit. Please note
that the height of the floor including tiles must be at least 48 mm and must not
exceed 60 mm!
• Please also note that the cut-out in the tiles must be at least 65 mm and at most
70 mm in diameter!
MIXER (SCHRITT 7-8):
You may now install the mixer and connect it to the concealed unit.
In order to do so, proceed as follows:
• First connect the spout to the fitting. Place the spout on the fitting and tighten the
grub screw on the underside of the spout.
• Place the fitting on the concealed unit in the floor. For this purpose, the connections
on the bottom of the fitting must be firmly seated in the corresponding holes of the
flush-mounted unit.
• Tighten the three screws on the base plate of the fitting, as shown in the sketch.
• Open the water supply to the mixer.
5
6
7
8
min. 65 mm
max. 70 mm
!
max. 60 mm
max. 48 mm