![Vallfirest BP4 User Manual Download Page 8](http://html1.mh-extra.com/html/vallfirest/bp4/bp4_user-manual_3244783008.webp)
8
OVERHEAT
OVERSPEED
Electronic over-speed cut-out system
MANT.
WARM UP
RESET-
MANT.
Maintenance
Cold motor
warning
Motor
overheating
Motor off if there is a pump filling
loss
RESET button for maintenance
warnings
CONTROL PANEL
1.
RESET - MANT.
: Hold down for 5 seconds to reset the
maintenance warning indicator.
2.
WARM UP
: This indicator turns on when the motor is too
cold to operate.
3.
MANT.
: This indicator turns on after 20 hours of operation.
Do all maintenance operations indicated in this instructions
manual on pg. 15. Reset after completing maintenance.
4.
OVERSPEED
: This indicator turns on when the motor pump
is working too hard; it lowers the accelerator speed.
The motor stops automatically if the unit may be damaged.
If the motor turns off, pull on the pull cord again with the
button in the ON position to re-start.
5.
OVERHEAT
: This indicator turns on when the motor
overheats. It lowers the motor speed to 1/4 to lower the
operating temperature range and the fan continues to operate.
If the problem persists, stop the motor completely and refer to
troubleshooting pg. 29.