Operation – Using the Pump (continued) 

 

18 

4. Pressure 

Switch 
Operation 

The pressure switch reacts to outlet pressure, and interrupts power at the 
preset shut-off pressure indicated on the pump label.  When outlet pressure 
drops below a predetermined limit the switch will close and the pump 
operates until the shut-off pressure is achieved.  The shut-off pressure is set to 
factory calibrated standards. 

Note:  If the plumbing is restrictive or the flow rate is very low, the 
pump may re-pressurize the outlet faster than the fluid is being 
released, causing rapid cycling (*ON/OFF within 2 seconds).  If the 
pump is subjected to rapid cycling during normal operation, or for 
infrequent periods, damage may occur.  Applications which exhibit 
rapid cycling should have restrictions in the outlet minimized. 
 

5. Leaving 

unattended 

If the pump must be left unattended at any time

:  

a)

 

Disconnect power to the pump. 

b)

 

Relieve system pressure. 
 

6. Discontinue 

use if 
clogged or 
inoperative 

 

If the pump becomes clogged or inoperative during use, discontinue use 
immediately
.

   

 
- DO NOT attempt to service while chemicals are in the pump and power is 

connected.   

- Return to service area to review instructions for troubleshooting before 

attempting to service. 

 

 

CAUTION 

 

 

DO NOT

 operate the pump at pressures which cause the motor to exceed the amperes rating 

indicated on the name plate. 

 

Improper adjustment of the pressure switch setting may cause severe overload or premature 
failure.  Failures due to improper adjustment of the pressure switch setting will not be 
covered under the warranty. 

 

 

 

Note: A reserve, clean container capable of holding at least the volume of the entire pump system 

should be kept for use when the pump system needs to be emptied temporarily for repairs. The 
container should be properly labeled as to its contents if it is used. 

 

 
 
 
 

 

 

Summary of Contents for EVERFLO EFHP1011-QA

Page 1: ...als could result in serious injury or illness to the operator or nearby persons animals or could cause damage to the environment This pump is recommended for use in spraying non flammable liquids such...

Page 2: ...Hazard Signal Word Definitions 2...

Page 3: ...our Check and test completed assembly 11 Operation Important Safety Information Operation 12 General Chemical Safety Chemical Applicator Safety Chemical Accident Procedures Preparing the Pump for Each...

Page 4: ...pump is NOT intended for use in spraying pesticides in dry or aerosolized form or for use with fumigants SPRAYING OTHER LIQUIDS In addition to spraying pesticides this pump may be used to spray other...

Page 5: ...al label WEAR protective clothing eye protection and chemical resistant gloves when operating the pump Wear additional protective gear such as facemask or apron as recommended on the chemical label EX...

Page 6: ...rson 1 Immediately follow First Aid instructions on chemical label General procedures can include a Eyes immediately flush with water b Skin wash all contaminated skin surfaces with soap and water c C...

Page 7: ...oduct Support at 1 800 864 1649 Part Description Model 798358 EFHP SERIES 1011 QA EFHP1011 QA 797056 EFHP SERIES 1015 EFHP1015 797008 EFHP SERIES 1015 QA EFHP1015 QA 797402 EFHP SERIES 1515 EFHP1515 7...

Page 8: ...9 5mm Inside diameter 3 8 9 5mm Inside diameter EFHP1515 QA 3 4 Quick Connect 3 8 9 5mm Inside diameter 3 8 9 5mm Inside diameter NOTE Everflo does not recommend the use of metal fittings or rigid pi...

Page 9: ...or with any non insulated tools If battery acid contacts skin or clothing flush immediately with water and neutralize with baking soda 2 Electrical requirements The pump should be on a dedicated indiv...

Page 10: ...connect the pump s black wire from the negative terminal of the battery c Disconnect the pump s red wire from the positive terminal of the battery d Reconnect the vehicle battery ground wire Note Skip...

Page 11: ...Never modify the pump design 1 Check assembly Check assembly to assure the pump is properly assembled and in safe working condition 2 Test with water Test the system for leaks with water a Fill the ta...

Page 12: ...ng or coming into contact with the chemical Personal protective equipment ALWAYS wear protective clothing eye protection and chemical resistant gloves when operating and cleaning the pump Wear additio...

Page 13: ...mical manufacturer Excess pesticide can be dangerous to humans damage desirable plants and contaminate soil and water sources Children pets ALWAYS exercise extra caution when spraying near areas acces...

Page 14: ...emical label c Clothing remove contaminated clothing immediately Dispose of heavily contaminated clothing per the instructions on the chemical label for safe chemical container disposal 2 Seek medical...

Page 15: ...materials like ground corncobs or pet litter should be spread on the spill area to soak up the pesticide The contaminated material should then shoveled into a leak proof container Do not flush the sp...

Page 16: ...a safety hazard or poor operation of the sprayer 1 Ensure clean system Ensure the pump has been thoroughly flushed and drained of all residual chemicals from prior uses 2 Inspect repair Inspect and te...

Page 17: ...area Clear the work area of all bystanders and pets Restrict access by the public for the period recommended on chemical label Step Two Operate the pump WARNING ALWAYS wear personal protective equipm...

Page 18: ...nded If the pump must be left unattended at any time a Disconnect power to the pump b Relieve system pressure 6 Discontinue use if clogged or inoperative If the pump becomes clogged or inoperative dur...

Page 19: ...ticide is to be stored for future use Store all unused pesticide in its original or a suitably marked container in a secure location out of the reach of children animals b If remaining pesticide is to...

Page 20: ...our RV antifreeze into the pump system Note RV antifreeze is non toxic and biodegradable and generally safer for the environment than automotive antifreeze 2 Spray briefly Turn on the pump and run the...

Page 21: ...icing your pump 2 Review troubleshoot ing table Review the Troubleshooting Table below for the type of problem you are experiencing However DO NOT attempt to repair until the steps listed below are fo...

Page 22: ...fittings Replace cracked fittings Worn diaphragm Replace diaphragm assembly Worn valves Replace valve plate assembly Inlet Outlet tube restriction Remove restriction Incorrect voltage Check voltage 10...

Page 23: ...previously sold Any Questions Comments Problems or Parts Orders Call Everflo Product Support 1 800 864 1649 Model Number Electrical connection Maximum amp draw Maximum flow Maximum pressure Ports Ove...

Page 24: ...ption EF QC A12 Quick Connect x 1 2 Hose barb EF QC A34 Quick Connect x 3 4 Hose barb EF QC EL34 Quick Connect x 3 4 Hose barb elbow EF QC EL38 Quick Connect x 3 8 Hose barb elbow EF QC EL12 Quick Con...

Page 25: ...1 798160 Motor assembly 1 2 798373 Base plate assembly 1 3 798163 Diaphragm assembly 1 4 798797 Valve plate assembly 1 5 798204 Upper housing assembly 1 6 797011 Pressure switch assembly 1 7 792140 Q...

Page 26: ...Qty 1 791824 Motor assembly 1 2 786945 Base plate assembly 1 3 797013 Diaphragm assembly 1 4 798397 Valve plate assembly 1 5 797104 Upper housing assembly 1 6 797889 Pressure switch 26815151 1 797086...

Page 27: ...on Qty 1 791824 Motor assembly 1 2 786945 Base plate assembly 1 3 797013 Diaphragm assembly 1 4 798397 Valve plate assembly 1 5 797105 Upper housing assembly 1 6 797889 Pressure switch 26815152 1 7970...

Page 28: ...arranty This warranty covers parts only It will not provide for replacement of complete products due to defective parts Components not manufactured by Everflo are guaranteed by their manufacturer and...

Page 29: ...29 This page left intentionally blank...

Page 30: ...30 Everflo A Brand of Valley Industries 180 Lake Ave N Paynesville MN 56362 www everflopump com Made in China 798835_Rev A...

Reviews: