![VALLEY FORGE & BOLT SPC4 406A User Manual Download Page 22](http://html1.mh-extra.com/html/valley-forge-and-bolt/spc4-406a/spc4-406a_user-manual_3237352022.webp)
VALLEY FORGE & BOLT MANUFACTURING COMPANY
PHONE: (602) 269 - 5748
4410 W. Jefferson St. • Phoenix, AZ 85043 • USA
WEB: www.vfbolts.com
SPC4™ SYSTEM • MODEL 406A • USER’S MANUAL
Rev. 1.0
- Page 20 of 21 -
5.0.0
Troubleshooting
The SPC4™ System is designed to be accurate, reliable, and easy to use. If a problem occurs
during operation, follow the steps listed below to determine the source of the problem.
[1]
Re-read the operating instructions. Pay attention to
“NOTES”
and
“CAUTIONS”
[2]
Check battery functionality
1.
Open the battery compartment to visually inspect the battery connections.
2.
Remember to close the battery compartment afterwards.
[3]
Check the cleanliness of the probe sensor and SPC4™ fastener datum disc.
1.
Inspect probe sensor and SPC4™ fastener datum disc for debris or dirt. Most of the erroneous
load measurements are the result of a dirty probe and/or dirty datum disc.
2.
Check both surfaces periodically for metal chips, liquids, dirt, and accumulated oxidation on
the contact surfaces. Foreign matter accumulating between these surfaces will radically affect
the load measurements.
Figure 20 – Probe Sensor Cleanliness
Dirty or contaminated
probe sensor face
Probe sensor face visually clean using a
clean lint-free dry cotton cloth
Summary of Contents for SPC4 406A