background image

Summary of Contents for VA5000

Page 1: ...VA5000 VALET Burglar Alarm Installation and Operation Manual ...

Page 2: ...G PROCEDURE 3 D PROGRAMMING OFCONTROLUNITS 4 ACCESS CODE 5 CLOCK 5 HORN DURATION 5 ZONING 6 ENTRY EXIT TIME DELAY 8 AUTO MODE 9 E ALARM ACTIVATIONRECALL 10 F REMOTE KEYPAD 11 G TELEPHONE DIALLER 12 H RADIO REMOTE CONTROL 13 I GENERAL NOTES 14 J TROUBLESHOOTING 16 WIRING INSTRUCTIONS 17 ...

Page 3: ...rious features of the VA5000areasfollows Micro Processor basedcontrol unit with memory analysis 4 Digit Code Access RemoteKeypad for the Front Door Zoning abilityto segregate different areas Zones sothat partsof ahome can havedetectorsswitchedon while otherareasareswitched off Variable Entry Exit Delay Variable Horn Time Options Remote Control An optional Hand Held Remote Control Unit is used to r...

Page 4: ...etectorcan be programmed into one or several zones to provide total flexibility with respect to the areas you wish to be covered 5 Entry Exit Time Delay Thesystem allowsyouto select thelengthof time thatyou require in order to leave the home after arming the system as well as the time you require to enter the home and disarm1 the system In addition you can determine which detectors you wish to be ...

Page 5: ...blue button 2 Zone Activation Deactivation If you wishto change thezonesthat are activated deactivated i Enterthe access code 4 numbers Display willshow GO ii Pushtheactivation deactivation zone button Display willshow Zone iii Pushtheappropriatezone number onthecontrol panel i e 1 2 3or4 Display will not change zone will turn ONorOFF iv Push O K button push Cancel button Note Theremote arm disarm...

Page 6: ...ode the control panel will display the word GO which is an indication that you can proceed to change or enter any of the functions or alternatively arm or disarm1thesystem The procedure for entering any of the program functions is to push the relevant button behind the control flap enter the information by use of the keypad andthen push the O K button to lock the information into memory The clear ...

Page 7: ...edure to set the time is asfollows a Enter access code Display will show GO b Lift flap and press Time of Day button Displaywill showT c Enter time by pressing appropriate numberson keypad e g if the time is 2 30 p m press keys 1430 or if the time is 7 30a m press keys730 d Press O K button Display will show GO e Presscancel button time of day will bedisplayed iii HORN DURATION The Horn Durationti...

Page 8: ...or groups of detectors are included in the various zones b Pre Programmlng The control panel hasinitially been programmed such that all stations groups of detectors areset into Zone 1 and Zone 1is activated c Programming In view of the fact that the system has automatically been programmed as above it will be necessary to remove from Zone 1 anystations thatarenot connected to detectors Unless thes...

Page 9: ...n 1 Display will show Zn 2V e Push O K button Display will show Zn 2 f Push button 2to enter station 2 into Zone2 Display will show Zn 22 g Push O K button Display will show Zn 2 h Repeat procedure to enter the various stations groups of detectors that you require to beentered intoZones i Push cancel button time of day will bedisplayed j Youcancheck your programmed zoning by pushing the station se...

Page 10: ...e for changing the entry exit delay times and or the entry exit delay path is as follows 1 Enter accesscode Display will show GO 2 Pressexit entry button under lift up flap Display will show IN 3 Enter required entry delay time e g 30 seconds Display will show 0030 4 Press O K button to lock in entry delay Display will show OUT 5 Enter required exit delay time e g 30seconds Display will show 0030 ...

Page 11: ...delay path vi AUTOMATICMODE The Automatic Mode enables you to program the system such that it automatically arms and disarms itself at pre set times e g if all the family areawayfromthe homefor asetperiod eachday the automatic mode can be used to automatically arm and disarm the system at pre set times onadaily basis a Enter accesscode Display will show GO b PressTime ON OFF button behind lift upf...

Page 12: ...n behind the control flap Onthe pushing of this button the system will display the time of the last alarm together with the circuit that caused the alarm The alarm memory can becleared by 1 Entering the accesscode Display will show GO 2 Push alarm activation button under control flap Display will showdetails ofalarm 3 Push clear1 button followed by O K button 4 Push cancel button to restoretime of...

Page 13: ...back door The remote keypad also incorporatesa panic button facility and can also belocatedin abedroomand used to arm and disarm the systemas well asact as a panic facility To activate the panic button from the keyboard push two blue buttons simultaneously The remotekeypad isoperated by afour 4 digit code which can beselectedand changed asfollows REFER KEY PAD WIRINGDIAGRAM FOR CODING 11 ...

Page 14: ...enerally be issued by the Security Agency and maycomprise up to six digits Please note There areseveralalternative codingsystems andtheequipment used by some Security Agencies may not be compatible with the Valet system To program telephone numbers i Enter access code 4numbers Display will show GO ii Press Phone No button behind flap Display will show Ph iii Press 1 on the keypad for Phone No 1 iv...

Page 15: ...ried in a handbag brief case or in the car Thesystemcanbe armed and disarmed from outside your home andassuch you do not require anyexit entry delay andall detectors canbeon instant alarm Inaddition youdo not haveto enter your accesscode eachtimeyou wish to arm or disarm the system The Hand Held RemoteControl also includes a panic bunon that enables you to activate an alarmby the push of a button ...

Page 16: ...entering STDtelephone numbers 7 Error If the display showsthe word error this meansthat an incorrect entry has been made simply pressthe cancel keyandthe display will revertto GO You can either continue with programming or press cancel button to revert to time of day 8 Forgotten Access Code If you forget your access code a Disconnect telephone plug if telephone dialler is installed b Turn off powe...

Page 17: ...ached should beremovedandthe horn duration set to zero To change the internal battery the following procedure should be adopted a Enter Access Code b Sethorn duration timeto Zerobypressing Horn Duration button and Zero time c Press O K d If atelephone dialler is fitted removetelephone plug fromsocket e Turn off power Disconnect the power supply f Open battery cover and replace battery making sure ...

Page 18: ...resto detectors areshorted cut or broken ii Detector hasterminating resistor seeInstallation procedure iii Detector isoperating correctly seeInstallation procedure iv All stationsare in correctzones 4 AL L Alarm Check keypadtamperswitch Alarm will not Operate Check the following 1 Horn duration is not set to zero 2 All stationsare in correctzones 3 All radio linked detectorsare set up to correct s...

Page 19: ...ver and Tamper Switch Passive Infra red Detector Passive Infra red Detector 000 ODD oaa ooa Coded Key Pad Option s Reed switches remote panic switches smoke andbreakingglass detectors Optional Telephone Dialler to Telecom611Mode 3socket see page 12for details y 4core shielded security cable 3 partelephonecable 2 metres of cable and socket are provided with the master station 17 ...

Page 20: ...r switch 4 For the Strobe Connect asshownasDiagram2 to terminals 5and fi 5 For the Key Pad Connect as shown onDiagram 4 6 For the Battery Firstly removethe battery cover from the Master Unit as shownon Diagram Connect the REDlead inside the Master to the RED terminal on the battery 4 Connect theBLACK lead inside the Master to theBLACKterminal onthe battery Place battery inside the Master and repla...

Page 21: ...AND THE BATTERY DISCONNECTED FAILURE TODO SO WILL CAUSE DAMAGETOYOUR SYSTEM AND VOID THE WARRANTY it BEFORE TURNING THE SYSTEMON 1 CONNECT THE BATTERYFIRST REPLACETHE BATTERYCOVER AND 2 TURN THE POWER ON AT THE POWER POINT IT IS ESSENTIAL THAT THIS SEQUENCE BE FOLLOWED WHENEVER ALL POWER IS REMOVED FROM THE SYSTEM FORWHATEVER REASON 19 ...

Page 22: ...LUE S HIUF WHITi WH 1 1k JUJ L Ms c r4 f Jl S rS HORN COVER WITH f RESISTOR 1 TAMPFR SWITCH l r l fl E It I B P XTERNAL HOP 1 v i 1 RFD II J I V j BLACK TERNAL HORN fi R ii i J DUJ n 1 1 H i r ni ULUE JJ V WHITE L ECJlftO VALET 0 9 X 4 e o e o 0 a i 1 2 3 8 9 10 11 12 13 1 15 16 17 18 19 20 21 22 t 2v Battery Ov PANIC REP BLACK h D STROBE V BLAC BLUE 7 V WH1TE S STATION 1 STRC LIGH STATION 2 STATI...

Page 23: ... When installing additional detectors six 6 to eight 8 repeat the wiring procedure as for detectors two 2 to four 4 eg Detector 6 in series with detector two 2 on STATION 2 terminating a the red wire onto terminal 1 b the black wire onto terminal 2 c the blue wire onto TERMINAL 11 d the white wire onto terminal 12 and remove the 4K7 resistor from terminals 11 12 SYSTEMS WITH MORE THAN EIGHT 8 P I ...

Page 24: ...nnot use the same number twice i e 1241or 5357 will not work NOTE it is not essential to have the same code number on the key pad as on the control panel since the control panel code can have all four 4 numbers the same i e 7777 if required Attach the colour coded wire A on the key pad to the pin that relates to the first number of the chosen access code i e if access code selected is 4579 then co...