Technical data
Thermo H
77
Note:
The circuit breaker rating is based on the maximum operating voltage. The rating must be adapted to the highest operating current and
the temperature derating of the circuit breaker.
Electrical part (high voltage)
Device version
AC070
AC090
AC140
AC200
DC070
DC070
DC200
DC 140
Nominal heating flow max.
kW
7
9
14
20
7
7
20
2x 7
Rated voltage
V
400
690
600
690
600
Rated control voltage
V
24
Control voltage min.
V
20.4
16
Control voltage max.
V
26.4
32
Power consumption
kW
7
9
14
20
7
7
20
2x 7
Frequency
Hz
50-60
--
Rated current
A
9.9
13.5
19.75
29.6
9.9
11.8
29.6
2x 11,8
Electrical protection
A
16
16
25
32
16
16
35
2x 16
Insulation resistance new device
at 1000V
M
Ω
> 100
Insulation resistance at the end of
life at 1000V
M
Ω
> 50
Summary of Contents for Thermo H