6 Wiring diagrams
Fig. 612 Small distribution board removal for devices Thermo DC 20 kW without converter
(heater ident. no. acc. to model plate 11125621A)
Fig. 613 Small distribution board removal for devices Thermo DC 20 kW without converter
(heater ident. no. acc. to model plate 11126153A)
AC
Connecting HLP / Anschluss HLP
HLP
orange cable
(oranges
Kabel)
blue cable
(blaues
Kabel)
1
AC4
N5
2
AC5
N6
3
AC3
N3
4
AC9
N11
5
AC8
N10
6
AC7
N9
7
AC2
N2
8
AC1
N1
9
AC6
N7
Contactor / Schütz
DC
Connecting HLP / Anschluss HLP
HLP
orange cable
(oranges
Kabel)
blue cable
(blaues
Kabel)
2
DC11
DC7
3
DC5
DC19
4
DC4
DC20
5
DC2
DC17
6
DC12
DC6
7
DC10
DC3
8
DC9
DC1
9
DC8
DC18