615
REVO-E Heat pump
6 Wiring plan
6.4
Frequency converter - electrical connections
6.4.1 600V DC power supply including HVIL connector
The air-conditioning system is linked to the HVIL monitoring system via the 600V DC wiring harness.
Inspect the operating voltage at the connections L1 (Pos1) and L3 (Pos2) with the designated voltage tester
(CAT IV), see
.
Fig. 603
Power supply 600V DC including HVIL connector
No.
Designation
Configura-
tion
Cable color
1
L1
DC network
(+)
Red
2
L3
DC network (-
)
Blue
3
HVIL in vehicle
X61 Pin 1
White
4
HVIL out of vehicle
X61 Pin 2
Brown
5
HVIL in system
X61 Pin 1
Pink
6
HVIL out of system
X61 Pin 2
Brown
4
3
5
6
7
1(L1)
2(L3)
Strip
No.
Designation
Configura-
tion
Cable
color
Cable
no.
X5
10
EN-HW
Approval
Yellow
4
16
A GND
(Ground 10V)
Ground
Gray
3
17
A. In 1
Desired
speed of
compressor
Brown
6
X6
1
Com
Center con-
tact of relay 1
Green
5
3
NC
Break con-
tact of relay 1
White
7
Application map
Cable assignment for application map
Summary of Contents for REVO-E
Page 1: ...Rev 06 2019 Id No 11123006A REVO E Heat pump Volvo Workshop Manual AIR CONDITIONING...
Page 51: ...605 REVO E Heat pump 6 Wiring plan Fig 601 Wiring diagram for REVO E HP Sheet 4...
Page 52: ...606 REVO E Heat pump 6 Wiring plan Fig 601 Wiring diagram for REVO E HP Sheet 5...
Page 55: ...609 REVO E Heat pump 6 Wiring plan Fig 602 Wiring diagram for REVO E HP Sheet 1...
Page 56: ...610 REVO E Heat pump 6 Wiring plan Fig 602 Wiring diagram for REVO E HP Sheet 2...
Page 57: ...611 REVO E Heat pump 6 Wiring plan Fig 602 Wiring diagram for REVO E HP Sheet 3...
Page 59: ...613 REVO E Heat pump 6 Wiring plan Fig 602 Wiring diagram for REVO E HP Sheet 5...
Page 87: ...memos...