delay, the controller will switch on the load. The load will 
be switched off after working for a pre-set time. 

15 

Manual mode 

The user can switch the load on or off by the keys, no 
matter whether it

s day or night. This mode is designed for 

some specifically purposed loads, and also used in the 
debugging process. 

16 

Debugging mode 

Used for system debugging. With light signals, the load is 
shut off; without light signals, the load is switched on. This 
mode enables fast check of the correctness of system 
installation during installation debugging.  

17 

Normal on mode 

The energised load keeps outputting, and this mode is 
suitable for loads which need 24 hour power supply.  

 

Manual operation is effective only when the load mode is manual mode (15), and tap the Set key to 
switch on/off the load under any main interface. 

Under any interface other than load modes, press and hold the Set key to enter into the parameter 
setting interface.  

 

After entering into the setting interface, tap the Set key to switch the menu for setting, and tap the 
Up or Down key to increase or decrease the parameter value in the menu. Then tap the Return key 
to exit (without saving parameter setting) or press and hold the Set key to save settings and exit.  

NOTE:

 After system voltage setting, power supply has to be switched off and then on again, 

otherwise the system may work under an abnormal system voltage.  

Summary of Contents for MPPT 30A

Page 1: ......

Page 2: ...urately track the maximum power point A built in maximum power point tracking algorithm can significantly improve the energy utilisation efficiency of photovoltaic systems and raise the charging effic...

Page 3: ...linear proportion to the temperature so as to cur the temperature rises of the controller effectively keeping the controller from being damaged by overheat Featuring a temperature compensation functi...

Page 4: ...voltage is around 12V when charging with a conventional solar controller the solar panel s voltage will stay around 12V failing to deliver the maximum power However the MPPT controller can overcome th...

Page 5: ...ise charging and boost charging the two of which are not carried out in a repeated manner with the former getting activated once every 30 days Boost Charging by default boost charging generally lasts...

Page 6: ...o be maintained at full state At this stage the loads can access almost all the solar power If the loads consume more power than the solar panel could provide the controller will not be able to keep t...

Page 7: ...d space where battery gas may accumulate WARNING DANGER OF HIGH VOLTAGE Photovoltaic arrays may produce a very high open circuit voltage Open the breaker or fuse before wiring and be very careful duri...

Page 8: ...oltage Open the breaker or fuse before wiring and be very careful during the wiring process WARNING RISK OF EXPLOSION Once the battery s positive and negative terminals or leads that connect to the tw...

Page 9: ...e and it s recommended that installation distance be not more than 150mm If no remote temperature sensor is connected to the controller the battery temperature value will stay at 25 C If an inverter i...

Page 10: ...uick Flashing A cycle of 2s on off lasting for 0 1s Load overload short circuited Steady On Load functioning normally Off System operating normally Steady On System malfunctioning UP Page up increase...

Page 11: ...day time off When no sunlight is present the solar panel voltage is lower than the light control on voltage and after a time delay the controller will switch on the load when sunlight emerges the sola...

Page 12: ...outputting and this mode is suitable for loads which need 24 hour power supply Manual operation is effective only when the load mode is manual mode 15 and tap the Set key to switch on off the load un...

Page 13: ...ery is reversely connected the system will not operate so as to protect the controller from being burned PHOTOVOLTAIC INPUT IDE TOO HIGH VOLTAGE PROTECTION If the voltage on the photovoltaic array inp...

Page 14: ...nal screws firmly Check if there are any dirt nesting insects or corrosion and clean as required If the lightening arrester has lost its efficacy replace it with a new one timely to prevent the contro...

Page 15: ...72 5mm Over voltage cut off voltage 16 0V 16 0V 16 0V 9 to 17V Equalising voltage 14 6V 14 8V 9 to 17V Boost voltage 14 4V 14 2V 14 6V 9 to 17V Floating charging voltage 13 8V 13 8V 13 8V 9 to 17V Boo...

Page 16: ...must be followed Over voltage cut off voltage charging limit voltage equalising voltage boost voltage floating charging voltage boost return voltage Over voltage cut off voltage over voltage cut off...

Page 17: ......

Reviews: