Page 28
Owner’s Manual - L48
ENGLISH
- Inspect and ensure that the lighting of the main burner occurs within 4 seconds of the gas valve
opening. Visual inspection should match the information illustrated in the manual. Inspect primary
air openings for blockage.
- Check the glass and gasket for proper seal.
- Clean glass with a suitable fireplace glass cleaner. Abrasive cleaners must not be used. Be careful
not to scratch the glass when cleaning.
- Check all latches or other door retention components for proper operation, tension, and relief
mechanisms are free from obstructions.
- Check the barrier screen for fit and structural integrity.
- Inspect the log set (if applicable) and decorative media (if applicable) for debris or damage.
- Freshen up the glowing embers if applicable.
- Replace batteries in the remote transmitter and receiver if applicable.
- Inspect the venting and vent termination cap for damage, corrosion, sooting, or obstruction and
correct if present.
- Check all accessible gas-carrying tubes, connections, pipes and other components for leaks.
• In addition, clean and inspect the fireplace following any remodeling work in your home.
7.3 Light Bulbs replacement
BULB TYPE: 120V 35W G 6.35MM BASE
CAUTION
Turn off all power to the fireplace prior to changing bulbs or servicing the controls.
CAUTION
Sharp Edges! Use gloves and eye protection when servicing the fireplace controls.
Use gloves to avoid touching the bulb with bare hands.
1. Remove the barrier and the glass door assemblies.
2. Lift the light access cover up and out of
the firebox.
3. Remove the bulb(s) to be replaced.
Summary of Contents for L48