background image

2

947019

SYSTEM DESIGN

General

Valcom Amplified Recessed Ceiling Speakers may be
used to provide one-way paging from any Valcom
one-way or talkback page control.  The speakers can
also be used to expand existing 70V paging systems.
When power and appropriate input signal are applied,
a voice page can be made.

Page Control Access

(See Figure 1)
When using the Amplified Recessed Ceiling Speakers
with a Valcom page control, the following equipment
will be required:

 

Appropriate one-way speaker assembly

 

Valcom page control

 

Valcom power supply sized to provide power to
operate the amplified speaker assemblies and
page control

NOTE:  When using the Valcom one-way interior
speakers with a Valcom handsfree page control, it
is recommended that a V-1092 Volume Control be
connected between the zone output and the
speaker input.

25V or 70V Paging Systems

(See Figure 2)
When using the Amplified Recessed Ceiling Speakers
with an existing 25 or 70V paging system, the
following equipment will be required:

 

Appropriate one-way speaker assembly

 

Valcom power supply sized to provide power to
operate the amplified speaker assemblies

 

25 or 70V line transformer tapped at 1/4 watt
with an 8 ohm output

 

Valcom V-1094A Page Port Preamp/Expander

Special Applications

The Tip and Ring input of the amplified speaker may
be connected directly to the speaker in most
electronic key telephones to amplify the level of the
speaker.  A power supply is also required.

Speaker Cabling

All Valcom amplified one-way interior speakers
require 2 pairs to operate.  Standard telephone station
cable may be used.  Existing telephone wire and
feeder cables may also be used.  Refer to the
following tables when planning an installation.

 

Audio Pair:  The number of speakers looped on
the audio pair is not critical unless you have a
very large job.  Table 1 gives guidelines for the

number of speakers per audio run.

Table 1 - Number of Speakers per Audio Run

Wire Run (Ft)

22 AWG

24 AWG

100

150

120

200

150

120

400

100

60

800

50

30

1600

25

15

 

Power Pair:  The cable runs specified in Table 2
are very important and must be followed for
proper operation of the one-way paging speakers.

Table 2 - Number of Speakers per Power Run

(22 AWG)

Wire Run (Ft)

1 Watt Inside Speakers

100

60

200

30

400

15

800

7

1600

3

Coverage

The area covered by Valcom Recessed Ceiling
Speakers is determined by the height of the ceiling.  If
the ceiling height is 8', the speaker will cover 250 sq.
ft.  If the ceiling is 20 feet high, the speaker will
cover 1000 sq. ft.

INSTALLATION

Typical connections to a Valcom Page Adapter (refer
to Figure 1)

 

Connect screw terminal marked Tip to the tip
side of the desired speaker output of the page
control.

 

Connect screw terminal marked Ring to the ring
side of the desired speaker output of the page
control.

 

Connect -24VDC "B" battery (may be referred to
as "-" or "signal battery") from power supply to
screw terminal marked -24VDC on the speaker.

NOTE:  "A" battery may be substituted for "B"
battery connections.

Connecting arrangement to 25 or 70V paging systems
(refer to Figure 2)

 

Connect transformer primary side terminal
marked COM to Black wire or 25 or 70V line.

 

Connect transformer primary side terminal
marked 1/4 watt to White wire of 25 or 70V line.

 

Connect transformer secondary side terminal
marked "C" to one screw terminal input of the

Technical Manuals Online! - http://www.tech-man.com

firealarmresources.com

Reviews: