background image

 

2

 

 

Precautionary Designations 

 
Wiring

 

When using the VP-2024 with Valcom page 
equipment, a strap should be added from the local 
ground terminal to the ground output.  Refer to Figure 
1 for connections to a Valcom page control unit. 
 
When installing Valcom one-way amplified horns, 
connect the white and black wires of the horn t o the 
power supply -24V and GND terminals respectively. 
 
When installing Valcom one-way speakers, connect 
the -24V and GND terminals of the speaker to the 
corresponding power supply terminals. 

TECHNICAL ASSISTANCE

 

When trouble is reported, verify that AC power is 
being supplied to the unit. 
 
To test the power supply, remove all output 
connections and measure the output voltage with a 
meter.  If no voltage is measured, replace the unit. 
 
Assistance in troubleshooting is available from the 
factory.  When calling, you should have a VOM and a 
test set available and be calling from the job site.  Call 
(540) 563-2000 and ask for Technical Support, or call 
(540) 767-1555 for Valcom 24-hour Faxback System or 
visit our website at http://www.valcom.com. 
 
Valcom equipment is not field repairable.  Valcom, Inc. 
maintains service facilities in Roanoke, VA.  Should 
repairs be necessary attach a tag to the unit clearly 
stating your company name, address, phone number, 
contact person and the nature of the problem. Send 
the unit to: 

Valcom, Inc. 

Repair and Return Dept. 

5614 Hollins Road 

Roanoke, VA  24019-5056 

 

 
 
 
 

TROUBLESHOOTING CHART

 

 

 

 

PROBLEM 

 
 

ACTION TO BE TAKEN

 

 
1.  No Output 
 
 
2.  Blows Fuses 

 
a.  Verify AC present at receptacle. 
b.  Check for blown fuse. 
 
a.  Verify total equipment power consumption does not exceed 2 Amps. 
b.  Disconnect AC while making power connections. 

 
 
 

CAUTION:  To reduce the risk of electric shock,

Do not remove cover.

No user serviceable parts inside.

Refer servicing to qualified service personnel.

This symbol indicates that dangerous
voltage constituting a risk of electric
shock is present within this unit.

This symbol indicates that there are
important operating and maintenance
instructions in the literature accompanying
this unit.

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

 

Reviews: