947532
INSTALLATION
Mounting
The VL550AF message display with flasher
should be mounted with appropriate hardware
(not included). We recommend the display
base to be mounted into wall studs.
Network Connection / Power
The RJ-45 Ethernet port is accessible through
the cutout in the display base. Connect a
standard patch cable to the VL550AF from an
Ethernet switch supporting the Power over
Ethernet specification 802.3at (PoE+). If a
PoE+ switch is not available, a mid-span
injector may be used to supply power to the
display.
.
Setup
Information specific to your application will need
to be programmed into the VL550AF using a
computer. The PC used for programming
should be connected to the same subnet as the
VL550AF. Setup will be done using the IP
Solutions Setup Tool. Download the latest
version of the free IP Solutions Setup Tool from
the Valcom web site at
www.valcom.com/vipsetuptool.
The VL550AF audio output can be generated
from any Valcom IP Paging source, such as the
VIP-201A SIP Paging Server or a VIP-811A
Network Station Port. Message displays are
programmed and delivered by a Valcom
Engineered Solutions VE6025 Application
Server. Contact Valcom Engineered Solutions
for details on the VE6025 Application Server.