CAUTION:  To reduce the risk of electric shock,

Do not remove cover.

No user serviceable parts inside.

Refer servicing to qualified service personnel.

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

This symbol indicates that dangerous
voltage constituting a risk of electric
shock is present within this unit.

This symbol indicates that there are
important operating and maintenance
instructions in the literature accompanying
this unit.

INSTALLATION 

Precautionary Designations 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

FCC Information 

This equipment has been tested and found to 
comply with the limits for a Class A digital 
device, pursuant to Part 15 of the FCC Rules.  
These limits are designed to provide 
reasonable protection against harmful 
interference when the equipment is operated in 
a commercial environment.  This equipment 
generates, uses and can radiate radio 
frequency energy and if not installed and used 
in accordance with the instruction manual, may 
cause harmful interference to radio 
communications.  Operation of this equipment 
in a residential area may cause harmful 
interference in which case the user will be 
required to correct the interference at his own 
expense.  

 

Mounting

 

The VIP-804 is designed for wall, table or rack 
mounting. 

 

Table

: Provided with the VIP-804 are four rubber 

pads.  Peel the pads from their carrier backing 
and place at the four corners of the bottom of the 
unit. 

 

Wall

: Using the template on last page of this  

document, mark the location of the bracket screw 
holes on the wall.  Drill 5/64" pilot holes, 3/4" deep, 
at each screw location and use the wood screws 
provided to attach the brackets to the wall.  For 
surfaces other than wood, use hardware 
appropriate for the surface (not included).  With the 
brackets securely attached to the wall, attach the 
VIP-804 to the brackets using the included 
hardware.  Figure 2 illustrates the bracket 
assembly. 

 

Rack: 

Following the assembly drawing, attach the 

two mounting brackets to the VIP-804 unit.  Using 
rack screws, mount the VIP-804 in an available 1U 
rack slot.  See Figure 1. 

 

 
 
 
 
 
 
 
 
 
 
 

Figure 1. Rack Mount 

 

 
 
 
 
 
 
 
 
 
 

 
 
 
 
 

Figure 2. Wall Mount 

 

Power Connections 

The preferred method of powering a VIP-804 is via 
a Power over Ethernet (PoE) switch meeting the 
802.3af specification.  

 

If the rear panel barrel connector is used for power, 
the preferred power supply is a Valcom VIP-324D. 

 

Make all required signal connections before 
applying power to the unit.  If powering via PoE, 
make sure all signal connections via the back 
panel are made then connect the VIP-804 to the 
Ethernet switch.  

 

If power is supplied via the barrel connector, make 
sure all signal connections are secure.  Attach the 
unit to the network via the front panel RJ-45 
Ethernet connector.  Apply power by plugging the 
power supply into the     VIP-804 via the barrel 
connector on the rear of the VIP-804.