background image

 

                                                                  3                                                                         947311 

S

P

E

AK

E

R

LED 1

LED 2

-10
dB

 LIN

E

LEV

E

L O

U

T

M
U

TE

S

WI

TC

H

 2

S

WI

TC

H

 1

G

RO

U

N

D

NE

TWO

R

K

RESET

+

-

- +

RE

D

BL

AC

K

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Figure 3.  Mounting/Connections 

 

 

 
 
 
 
 

 
 
 
 
 
 
 
 

 
 
 
 

 
 
 
 
 
 

Figure 4. IP Clock/Speaker Connections 

 

Network Connection 

The VIP-4122-D44-IC has one RJ-45 network 
connector on the clock circuit board (D) in Figure 3.  
Connect a standard Ethernet patch cable from the 
VIP-4122-D44-IC into an Ethernet switch.   If a PoE 
switch is not available, a PoE mid-span injector may 
be used to supply power to the clock and speaker. 

Call Switch Connection 

For IP Speakers using Talkback functionality, a call 
switch input via screw terminals is provided.  
Connect a momentary contact switch to Switch 1 
and Ground. 

 

-10 dB Line Level Out Connection 

The -10dBm Line Level Out may be connected to 
up to 40 Valcom Self Amplified Speakers in order to 
provide additional sound reinforcement in an area

 
LED 1 and LED 2 Connection 

LED 1 (+) and LED 2 (-) is a current limited output 
designed to illuminate an optional LED.  The LED is 
intended to provide visual indication of call 
progress.  The LED illumination will flash when the 
call switch is pressed and will continue to flash until 
the call is answered.  The LED illumination will be 
solid when a connection to the unit is established. 

 

SETUP

 

The VIP-4122-A12-IC will automatically acquire an 
IP address (using DHCP) and connect to the 
InformaCast server when connected to the 
network and powered up. Information specific 
to your application will need to be programmed 
into the InformaCast server. Refer to the 
InformaCast documentation for further 
information 
 

TECHNICAL ASSISTANCE 

When trouble is reported, verify power is being 
supplied to the unit and there are no broken 
connections. If a spare unit is available, substitute a 
spare unit for the suspected defective unit. 

 

Assistance in troubleshooting is available from the 
factory. Call (540) 563-2000 and press 1 for 
Technical Support or visit our website at 
http://www.valcom.com or via email at 
[email protected]. Valcom equipment is not 
field-repairable. Valcom, Inc. maintains service 
facilities in Roanoke, VA.  Should repairs be 
necessary, attach a tag to the unit clearly stating 
your company name, address, phone number, 
contact person and the nature of the problem.  
Send the unit to: 

Valcom, Inc. 

Repair & Return Dept. 

5614 Hollins Road 

Roanoke, Va. 24019-5056 

 

WARRANTY 

Warranty information may be found on our website 
at www.valcom.com/warranty.

 

 