CAUTION:  To reduce the risk of electric shock,

Do not remove cover.

No user serviceable parts inside.

Refer servicing to qualified service personnel.

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

This symbol indicates that dangerous
voltage constituting a risk of electric
shock is present within this unit.

This symbol indicates that there are
important operating and maintenance
instructions in the literature accompanying
this unit.

Precautionary Designations 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

FCC Information 

This equipment has been tested and found to 
comply with the limits for a Class A digital 
device, pursuant to Part 15 of the FCC Rules.  
These limits are designed to provide 
reasonable protection against harmful 
interference when the equipment is operated 
in a commercial environment.  This 
equipment generates, uses and can radiate 
radio frequency energy and if not installed 
and used in accordance with the instruction 
manual, may cause harmful interference to 
radio communications.  Operation of this 
equipment in a residential area may cause 
harmful interference in which case the user 
will be required to correct the interference at 
his own expense.  

 

Mounting

 

The VE8021 is designed for wall or table 
mounting. 

The VE8021R is designed for 19” rack 

mounting (1U). 

 
Table: 

Provided with the VE8021 are four rubber 

pads.  Peel pads off their carrier backing and 
place at the four corners of the bottom of the unit.

  

 
Wall: 

Secure mounting brackets with screws 

provided to the VE8021, then secure the VE8021 
to the wall.  See Figure 1. 
 

Rack:  

Secure mounting brackets with screws 

provided to the VE8021R.  See Figure 1.  Place 
the VE8021R into a 

standard 19” rack and secure 

to rack with proper hardware (not included).

 
 
 
 
 
 
 
 
 
 
 
 

 

 

Figure 1. 

 

Power Connections 

The preferred method of powering a 
VE8021/VE8021R is via a Power over Ethernet 
(PoE) switch meeting the 802.3af specification. 

 

If the rear panel barrel connector is used for 
power, the preferred power supply is a Valcom 
VIP-324. 
 
Make all required signal connections before 
applying power to the unit.  If powering via 
802.3af, make sure all signal connections via the 
rear panel are made then connect the 
VE8021/VE8021R to the Ethernet switch.  
 
If power is supplied via the barrel connector, 
make sure all signal connections are secure.  
Attach the unit to the network via the front panel 
RJ-45 Ethernet connector.  Apply power by 
plugging the power supply in to the 
VE8021/VE8021R via the barrel connector on the 
rear of the VE8021/VE8021R. 
 

Network Connection 

The VE8021/VE8021R has one CAT-5 RJ-45 
network connector on the front panel. 
 
Use the supplied CAT-5 patch cable to connect 
the VE8021/VE8021R to an Ethernet switch.  If 
the Ethernet switch is 802.3af compliant the 
VE8021/VE8021R will draw power from it. 
 

Signal Connections 

On the rear panel, the VE8021/VE8021R has 3 
signal connectors on the rear panel: 

 

 

1 RJ-11 jack for connection to a FXS circuit 

 

1 RJ-11 jack for a failover telephone 
 connection 

 

1 terminal block for relay connections