3 947490
ADMIN I/O
.......................
.......................
STATUS
+24V DC
NETWORK
Power Connections
The rear panel barrel connector is used for
power. The preferred power supply is a Valcom
VP-1124D.
Make all required signal connections to a 66M150
punch block. Connect the block to the VE8006R
using a 25 pair, female Amphenol terminated
cable (NOT SUPPLIED) before applying power to
the unit. Plug the cable into the 25 pair jack
labeled ADMIN I/O on the back panel.
Attach the unit to the network via the RJ45
Ethernet connector. Apply power by plugging the
power supply in to the VE8006R via the barrel
connector on the rear of the VE8006R.
Network Connection
The VE8006R has one RJ45 network connector.
Use a standard Ethernet patch cable to connect
the VE8006R to an Ethernet switch.
Signal Connections
Signal connections are made via a 25 pair
Amphenol connector. (See figure 2)
Rear View
Setup
Information specific to your application will need
to be programmed into the VE8006R using a
computer. The PC used for programming should
be connected to the same subnet as the
VE8006R.
Setup will be done using the IP Solutions Setup
Tool. Download the latest version of the free
IP Solutions Setup Tool from Valcom web site
at www.valcom.com/vipsetuptool.
Status Indicator Lights
The VE8006R has 3 status indication lights on
the rear panel:
STATUS:
Illuminates at regular intervals during
normal operation. On steady indicates unit is in
reset mode. NOTE: The status LED will
illuminate steady during the initial power on boot
up sequence. Once the unit has successfully
booted, the status indicator will change to an
intermittent flash (approximately 1 second on/1
second off).
The network jack provides two LED indicators:
Green LED:
(Link) Indicates Ethernet connection
when illuminated.
Yellow LED:
(Activity) Indicator flashes to
indicate network activity.
TECHNICAL ASSISTANCE
When trouble is reported, verify power is being
supplied to the unit and there are no broken
connections. If a spare unit is available,
substitute a spare unit for the suspected
defective unit.
Assistance in troubleshooting is available from
the factory. Call (877) 427-2166 and ask for
Valcom Engineered Solutions Technical Support,
or visit our website at www.ValcomES.com.
Valcom equipment is not field repairable.
Valcom, Inc. maintains service facilities in
Roanoke, VA. Should repairs be necessary,
attach a tag to the unit clearly stating your
company name, address, phone number, contact
person and the nature of the problem. Send the
unit to:
Valcom, Inc.
Repair & Return Dept.
5614 Hollins Road
Roanoke, Va. 24019-5056