Valcom VE8001A Manual Download Page 3

 

                                                                 3                                                                 947825                                                              

AUX

IN

INPUTS

AUDIO   CC PAGE

1 2 3 4

+24V DC

K1

K2

NO

C

O

M

NC

NC

C

O

M

NO

AUX

OUTPUTS

ON

Network Connection 

The VE8001A/VE8001AR has one RJ-45 network 
connector on the front panel.  Use a standard 
Ethernet patch cable to connect the 
VE8001A/VE8001AR to an Ethernet switch.   
 
 
 
 
 
 
 

 

Rear View 

 

 
Signal Connections 

The VE8001A/VE8001AR has signal connectors on 
the rear panel: 

 

 

RCA jack for AUX audio input 

 

2 Audio outputs 

 

2 Form C relays  

 

1 Audio input 

 

1 Contact Closure input 

 

AUX Input: 

Local audio may be input via the 

rear panel RCA jack. Nominal input impedance  
is 600 Ohms.  Connect any compatible audio 
source using an RCA patch cable.  Audio 
supplied through the rear panel RCA jack is 
transformer coupled to both Audio Out terminals 
when paging is idle.  This is typically used for 
background music. 

 

Audio Out: 

Two audio output connections are 

provided.  The term

inals labeled “Page” provide a 

signal output compatible with Valcom self-amplified 
speakers.  Up to 40 Valcom speakers can be 
connected to the Page output.  The terminals 
labeled “AUX” provide a signal output compatible 
with most amplifiers and should be used where a 
transformer-coupled output is desired. 

 
DIP Switch:

  The four-pole DIP switch controls a 

supervision signal 

on the “Page” audio output line.  

For systems where supervision is used, setting DIP 
switches 1 & 2 to ON enables supervision on the 
Page audio output connections.  Where supervision 
is not used, set DIP switches 1 & 2 to OFF.  
Switches 3 & 4 are not used. 

Audio Input/Contact Closure:

  One Audio Input 

and one Contact Closure input are provided.  
Neither input is polarity sensitive.  The contact 
closure is labeled "CC".  The audio input  
terminals are labeled "AUDIO". 
 

Relay Channels: 

Access to the two form C relays 

is provided via a six pin screw terminal block.  The 
relays are labeled K1 and K2.  Each relay is 
brought out on three terminals.  The common 
contact is the middle terminal with the normally 
closed contact on the right and the normally open 
contact on the left.  Relay contacts are rated for 1A 
@ 24VDC. 

 
Status Indicator Lights 

The VE8001A/VE8001AR has 3 status indication 
lights on the front panel:  

 

STATUS: 

Flashes during normal operation and  

solid during system startup. 
 

Green LED:  

(Link) Indicates Ethernet connection 

when illuminated. 

 
Yellow LED: 

(Activity) Indicator flashes to indicate 

network activity. 

 

SETUP 

Information specific to your application will need to 
be programmed into the VE8001A/VE8001AR using 
a computer.  The PC used for programming should 
be connected to the same subnet as the 
VE8001A/VE8001AR.  Setup will be done using the 
IP Solutions Setup Tool.  Download the latest 
version of the free IP Solutions Setup Tool from the 
Valcom web site at www.valcom.com/vipsetuptool.