2 947990
Precautionary Notes:
NOTE: Unplug power cord and run off
battery box breaker before servicing.
INSTALLATION
The V-C6124P is designed for use with the
VP-9202 Dual 6A/4A Switching Power Supply
Shelf or Wall Mounting. The unit should be
mounted within 7 feet of an AC receptacle. A
local ground is provided through the AC cord.
Screw mounting plate to wall and position power
supply on mounting via the mounting slots.
Connections
Connections to Valcom page control units
are shown in Figure 1.
When using the V-C6124P with Valcom
page equipment, a strap may be added from
the local ground terminal to either of the "-"
outputs.
When installing Valcom one-way amplified
horns, connect the white and black wires of
the horn to the power supply "-" and "+"
terminals respectively.
When installing Valcom one-way speakers
connect the "-24VDC" an "GND" terminals of
the speaker to the "-" and "+" terminals
respectively.
Plug power supply into wall outlet.
Power supply activates after a 3 second
delay.
NOTE: Each 24VDC screw terminal is fused
by a 2 Amp poly switch automatic type fuse.
Therefore, when connecting equipment to
this power supply, the load should be
distributed between the (3) 2 Amp output
terminals and each load should not exceed 2
Amps.
TECHNICAL ASSISTANCE
When trouble is reported, verify there are no
broken connections. Troubleshooting
assistance is available from the factory. Call
(540) 563-2000 and press 1 for Technical
Support or visit our website at
http://www.valcom.com.
Valcom equipment is not field repairable.
Valcom, Inc. maintains service facilities in
Roanoke, VA. Should repairs be necessary,
attach a tag to the unit clearly stating company
name, address, phone number, contact person
and the nature of the problem. Send the unit to:
Valcom, Inc.
Repair and Return Dept.
5614 Hollins Road
Roanoke, VA 24019-5056
TROUBLESHOOTING CHART
Problem
Solution
1. No output.
2. LED pulses in reset
mode.
a. Verify AC present at receptacle.
b. Remove DC load and check for 24VDC using a VOM.
a. Locate and correct short circuit in output wiring.
b. Verify total equipment power consumption does not exceed 6
Amps.
CAUTION: To reduce the risk of electric shock,
Do not remove cover.
No user serviceable parts inside.
Refer servicing to qualified service personnel.
This symbol indicates that dangerous
voltage constituting a risk of electric
shock is present within this unit.
This symbol indicates that there are
important operating and maintenance
instructions in the literature accompanying
this unit.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN