SW2: Priority Port or Line 2 Battery Feed
No battery feed supplied to primary port
OFF
Battery feed supplied to primary port
ON
SW3 The 8-position dipswitch provides:
SW3-1: DTMF Signaling Options
No DTMF signal (single zone)
OFF
DTMF signal accepted (multi-zone)
ON
SW3-2, SW3-3: Number of digits to receive
before recording announcement.
1 digit
SW3-2 OFF
SW3-3 OFF
2 digits
SW3-2 ON
SW3-3 OFF
3 digits
SW3-2 OFF
SW3-3 ON
4 digits
SW3-2 ON
SW3-3 ON
SW3-4: Priority Port Mode
Records primary and priority pages,
Priority page broadcasts first
OFF
Priority page broadcasts in real time.
Primary page in progress is recorded and
is broadcast after priority page.
ON
SW3-5: Message Playback Control
Play message once
OFF
Play message twice
ON
SW3-6, SW3-7: Pre-Page Alert Tones
No Tone
SW3-6 OFF
SW3-7 OFF
Single Tone
SW3-6 ON
SW3-7 OFF
Dual Tone
SW3-6 OFF
SW3-7 ON
Quad Tone
SW3-6 ON
SW3-7 ON
SW3-8: Inter-Page Timing
1 second between pages
OFF
3 seconds between pages
ON
SW4 The 4-position dip switch provides:
SW4-1: Primary or Line 1 Page Access
Loop Detect
OFF
Audio Detect (VOX)
ON
SW4-2: Priority or Line 2 Page Access
Loop Detect
OFF
Audio Detect (VOX)
ON
SW4-3: Pre “Record” Tone (Enable/Disable)
Normal (3 sec. delay of “Ready to Record”
tone and “Recording Sequence”)
OFF
Enable
No tones are issued when “Recording
Sequence” is activated. Allows immediate
“Record Activation” with a contact closure.
ON
Disable
NOTE: This option is effective only when the inputs
are set at Loop Detect (SW 4-1 OFF).
SW4-4: Normal or Call Stacker Mode
2 Inputs – Primary and Priority
OFF
2 Inputs will function as Call Stacker
ON
Other Switches and Controls
SW5:
VOX Sensitivity - sets threshold for detection
of audio on the primary and priority ports.
SW5
Level
SW5
Level
0
-20dBm
8
-28dBm
1
-21dBm
9
-29dBm
2
-22dBm
A
-30dBm
3
-23dBm
B
-31dBm
4
-24dBm
C
-32dBm
5
-25dBm
D
-33dBm
6
-26dBm
E
-34dBm
7
-27dBm
F
-35dBm
LED Indicators
PLAY:
Illuminates when announcement is playing.
RECORD:
Illuminates during recording of the
announcement.
BUSY:
Illuminates if, for any reason the unit cannot
accept any more pages.
POWER:
Illuminates when –24 Vdc and GND is
applied to the unit.
TECHNICAL ASSISTANCE
When trouble is reported, verify the unit is turned on
and there are no broken connections leading to the
unit.
Assistance in troubleshooting is available from the
factory. When calling, you should have a VOM and a
telephone test set available and be calling from the
job site. Call (540) 427-3900 and ask for Technical
Support, or (540) 427-6000 for Valcom 24-hour
Automated Support or visit our website at
http://www.valcom.com.
VALCOM equipment is not field repairable.
VALCOM maintains service facilities in Roanoke,
VA. Should repairs be necessary, attach a tag to the
unit clearly stating your company name, address,
phone number, contact person, and the nature of the
problem. Send the unit to:
Valcom, Inc.
Repair and Return Dept.
5614 Hollins Road
Roanoke, VA 24019-5056