background image

3

947008

SW2:  Priority Port or Line 2 Battery Feed

No battery feed supplied to primary port

OFF

Battery feed supplied to primary port

ON

SW3      The 8-position dipswitch provides:

SW3-1: DTMF Signaling Options

No DTMF signal (single zone)

OFF

DTMF signal accepted (multi-zone)

ON

SW3-2, SW3-3: Number of digits to receive
before recording announcement.

1 digit

SW3-2 OFF

SW3-3 OFF

2 digits

SW3-2 ON

SW3-3 OFF

3 digits

SW3-2 OFF

SW3-3 ON

4 digits

SW3-2 ON

SW3-3 ON

SW3-4:  Priority Port Mode

Records primary and priority pages,
Priority page broadcasts first

OFF

Priority page broadcasts in real time. 
Primary page in progress is recorded and
is broadcast after priority page.

ON

SW3-5:  Message Playback Control

Play message once

OFF

Play message twice

ON

SW3-6, SW3-7:  Pre-Page Alert Tones

No Tone

SW3-6 OFF

SW3-7 OFF

Single Tone

SW3-6 ON

SW3-7 OFF

Dual Tone

SW3-6 OFF

SW3-7 ON

Quad Tone

SW3-6 ON

SW3-7 ON

SW3-8:  Inter-Page Timing

1 second between pages

OFF

3 seconds between pages

ON

SW4      The 4-position dip switch provides:

SW4-1: Primary or Line 1 Page Access

Loop Detect

OFF

Audio Detect (VOX)

ON

SW4-2: Priority or Line 2 Page Access

Loop Detect

OFF

Audio Detect (VOX)

ON

SW4-3: Pre “Record” Tone (Enable/Disable)

Normal (3 sec. delay of “Ready to Record”
tone and “Recording Sequence”)

OFF
Enable

No tones are issued when “Recording
Sequence” is activated.  Allows immediate
“Record Activation” with a contact closure.

ON
Disable

NOTE:  This option is effective only when the inputs
are set at Loop Detect (SW 4-1 OFF).

SW4-4: Normal or Call Stacker Mode

2 Inputs – Primary and Priority

OFF

2 Inputs will function as Call Stacker

ON

Other Switches and Controls

SW5:

VOX Sensitivity - sets threshold for detection
of audio on the primary and priority ports.

SW5

Level

SW5

Level

0

-20dBm

8

-28dBm

1

-21dBm

9

-29dBm

2

-22dBm

A

-30dBm

3

-23dBm

B

-31dBm

4

-24dBm

C

-32dBm

5

-25dBm

D

-33dBm

6

-26dBm

E

-34dBm

7

-27dBm

F

-35dBm

LED Indicators

PLAY:

  Illuminates when announcement is playing.

RECORD:

  Illuminates during  recording of the

announcement.

BUSY:

  Illuminates if, for any reason the unit cannot

accept any more pages.

POWER:

  Illuminates when –24 Vdc and GND is

applied to the unit.

TECHNICAL ASSISTANCE

When trouble is reported, verify the unit is turned on
and there are no broken connections leading to the
unit.

Assistance in troubleshooting is available from the
factory.  When calling, you should have a VOM and a
telephone test set available and be calling from the
job site.  Call (540) 427-3900 and ask for Technical
Support, or (540) 427-6000 for Valcom 24-hour
Automated Support or visit our website at
http://www.valcom.com.

VALCOM equipment is not field repairable. 
VALCOM maintains service facilities in Roanoke,
VA.  Should repairs be necessary, attach a tag to the
unit clearly stating your company name, address,
phone number, contact person, and the nature of the
problem.  Send the unit to:

Valcom, Inc.

Repair and Return Dept.

5614 Hollins Road

Roanoke, VA  24019-5056