Specifications

 

The timing and frequency specifications of the 
Valcom V-9923B code call unit are shown in Table 
2.  Figure 1 is a timing chart showing the nominal 
timing of a code call.   
 

Table 2 

Dial Tone Frequency 

180 Hz 

Coded Tone Frequency 

550 Hz 

Time Tones Broadcast 

370 ms 

Time between tones in a sequence 

500 ms 

Time between digits in a sequence 

1.5 sec 

Time between series of digits 

8 sec 

 
The Valcom V-9923B will detect 20-30 Hz ringing 
on the answer port.  The applied ringing voltage 
should be 75 to 125 Vac. 

 

 
 

DESIGN

 

The V-9923B provides two or three digit code call 
paging via a loop start trunk port on a PABX or by 
the use of a spare line button on a key system.  Figure 
2 is a simplified block diagram showing the code call 
unit and its connections. 
 

NOTE:  The code call unit is designed so that it will 
complete a code call sequence before resetting and 
returning dial tone, even if all parties hang up. 

 

Application

 

Key systems and PABX's used in: 

 

Department stores/shopping centers 

 

Hospitals, nursing homes 

 

Noisy locations, manufacturing plants 

 

Schools, universities 

 

Additional Materials Required

 

Additional equipment is required to complete a 
system when using the V-9923B.  These items are: 
 

 

-24 Vdc power supply (if existing supply 
inadequate or non-existent) 

 

66 type connecting block 

 

25 pair cable with a female amphenol connector 
on one end 

 

twisted pair crossconnect wire 

 
 

 

TONE ON

TONE OFF

.37  sec.

.50 sec.

1.5 sec.

1.5 sec.

8 sec.

"3"

"1"

"2"

"3"

"1"

SEQUENCE
   BEGINS

SEQUENCE
   BEGINS
    AGAIN

CONTINUES UNTIL
ANSWERED OR
CALLING PARTY
GOES ON HOOK

FIGURE 1

Summary of Contents for V-9923B

Page 1: ...t is installed SPECIFICATIONS The V 9923B is capable of providing code signaling for paging purposes it provides for meet me answer of code call and provides talk circuit and signaling tone Features T...

Page 2: ...stem Figure 2 is a simplified block diagram showing the code call unit and its connections NOTE The code call unit is designed so that it will complete a code call sequence before resetting and return...

Page 3: ...connect the V 9923B to a PABX are shown in Figure 4 The V 9923B requires a loop start trunk port from the PABX for access If more than one link of code call is being provided the second V 9923B would...

Page 4: ...ED TO PREVENT TWO CODES BEING BROADCAST SIMULTANEOUSLY The calling party then dials in a two or three digit number depending upon the position of dipswitch 1 on the code call unit After the last digit...

Page 5: ...he warranty period provided that 1 inspection by Valcom Inc indicates the validity of the claim 2 the defect is not the result of damage misuse or negligence after the original shipment 3 the product...

Page 6: ...K G G BK BK BR BR BK BK S S BK Y BL BL Y Y O O Y Y G G Y Y BR BR Y Y S S Y V BL 1 2 3 4 5 BL V V O O V V G G V V BR BR V V S S V 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30...

Page 7: ...KEY STRIP A1 H S PART OF KEY TELEPHONE INSTRUMENT FIGURE 5 CONNECTION OF V 9923B TO KEY SYSTEM V 9923B LS IN O W 4 BL BK 22 AG AB V BR 47 BR V 48 V S 49 BG V 9923B S V 50 BB 10 Vac LG AG GROUND AB 24...

Page 8: ...T CODES 111 119 121 129 991 999 OFF ON FIGURE 8 OPTION SWITCH SETTINGS LINE SUPERVISION BATTERY FEED RING DETECTOR K2 TONE OR ROTARY PULSE DECODING OSC AND AMPLIFIER LOGIC AND MEMORY K1 TT 40 RT 15 OU...

Reviews: