2

OPERATION

The V-2927 Clock Control Card installs into connectors J3 and J4 shown in Figure 1.  The output
connections are presented to the V-CIO Clock Interface Board via P2, DB15 male of the V-2927
Clock Control Card.  Two independent clock ports, consisting of two normally open contacts
each, are provided.  These ports work independently of each other and allow the system to
control two clock types simultaneously.  A status LED is provided for each relay to indicate
activity.  An administrative code, (#97XX, with XX being number of minutes to advance), is
provided to manually correct or advance various impulse clocks.

(Default code is 01).

INSTALLATION

The V-2927 must be installed prior to programming its available options.

WARNING:  Disconnect main power before servicing

!

  Remove the side plate and top cover of the Control Unit and set aside

  Remove and discard plate covering connector port opening for Clock Card DB15

  Remove four standoff nuts from Option Card

  Install 4 standoffs (shown in Figure 1)

  Connect J1 of Clock Card to J3 (shown in Figure 1)

  Connect J2 of Clock Card to J4 (shown in Figure 1)

  Press Clock Card firmly in place to make sure connectors are seated properly

  Install and tighten 4 standoff nuts on V-2927 board

  Replace top cover and side plate of the Control Unit and plug in the power supply

  Plug Clock Card connector into P2 (Clock Card Connector Port - See Figure 1 for location)

  Make connections to V-CIO board if mechanical clocks are being used (See Figure 2 for

location)

CLOCK TYPE CODES

Code

Description

Code

Description

01
02
03
04
05
06
07
08
09
10
11
12

Valcom Sync-wired 12-hour
Simplex sync-wired 24-hour
Generator start
Simplex 59

th

 minute

Utility impulse
European reverse
Honeywell Faraday
National time, hourly
Rauland, national time, 12-corr
Stromberg
Simplex, dual motor, 45

th

 minute

Simplex, dual motor, 59

th

 minute

13
14
15
16
17
18
19
20
21
22
23
24

Cincinnati D6
Cincinnati D3
Stromberg, 58

th

Standard electric time, FMT
Standard electric time, AR2
Standard electric time, AR3A
Dukane 24A
Dukane 240.  24 hour
Dukane 240.  12 hour
Standard electric GR
Simplex 1.8" digital 12-hour
Simplex 1.8" digital 24-hour

TECHNICAL ASSISTANCE

When trouble is reported, verify that power is being supplied to the unit and there are no broken
connections.  Check voltages for proper polarity on the cross connect block.

Assistance in troubleshooting is available from the factory.  When calling you should have a VOM
and a test set and be calling from the job site.  Call (540) 563-2000 and press 1 for Technical
Support or visit our website at http://www.valcom.com.

Valcom equipment is not field repairable.  Valcom, Inc. maintains service facilities in Roanoke,
VA.  Should repairs be necessary, attach a tag to the unit clearly stating company name, address,
phone number, contact person and the nature of the problem.  Send the unit to:

Valcom, Inc.

Repair and Return Dept.

5614 Hollins Road

Roanoke, VA  24019-5056