background image

14

947211

NOTE:

For Group page selection and Background Music Programming:

BGM Dialcodes

:

Group 1

Stations 1 – 6

#960

Background Music OFF

Group 2

Stations 7 – 12

#961

Background Music ON

Group 3

Stations 13 – 18

Group 4

Stations 19 - 24

TROUBLESHOOTING CHART

Problem

Corrective Action

No system operation.

 

Verify AC voltage is present at the receptacle.

 

Check the fuse located on the bottom of the unit.  If blown, replace with
a 1 amp, 250 VAC fuse.

 

Verify that 25 pair cable connectors are completely plugged into circuit
board connectors.

 

Refer to Figure 1 and verify all connections.

No paging at speaker.

 

Refer to Figure 1 and adjust volume.

Paging at speaker but no reply from
speaker.

 

Refer to Figure 1 and adjust volume.

No system ringing when call button is
pressed.

 

Verify all associated connections.

Background music not heard at speakers.

 

Verify connection of speakers and background music input.

No dial tone.

 

Refer to dip switch settings.

VALCOM LIMITED WARRANTY

Valcom, Inc. warrants its products to be free from defects in materials and workmanship under conditions of normal use and
Service for a period of one year from the date of shipment.  The obligation under this warranty shall be limited to the replacement,
repair or refund of any such defective device within the warranty period, provided that:

     1.   inspection by Valcom, Inc. indicates the validity of the claim,
     2.   the defect is not the result of damage, misuse, or negligence after the original shipment,
     3.   the product has not been altered in any way or repaired by others and that factory sealed units are unopened
           (A service charge plus parts and labor will be applied to units defaced or physically damaged),
     4.   freight charges for the return of products to Valcom are prepaid,
     5.   all units 'out of warranty' are subject to a service charge.  The service charge will cover minor repairs
           (Major repairs will be subject to additional charges for parts and labor).

This warranty is in lieu of and excludes all other warranties, expressed or implied, and in no event shall Valcom, Inc. be
liable for any anticipated profits, consequential damages, loss of time or other losses incurred by the buyer in
connection with the purchase, operation or use of the product.

This warranty specifically excludes damage incurred in shipment.  In the event a product is received in damaged condition, the
carrier should be notified immediately.  Claims for such damage should be filed with the carrier involved in accordance with the
F.O.B. point.

Headquarters:

Valcom, Inc.

1111 Industry Avenue

Roanoke, VA  24013

Phone:  (540) 427-3900

FAX:    (540) 427-3517

In Canada:

CMX Corporation

35 Van Kirk Drive #11 and 12

Brampton, Ontario L7A1A5

Phone:  (905) 456-1072

FAX:    (905) 456-2269

Summary of Contents for V-2924

Page 1: ...d all call pages Each station can be programmed for one way or two way communication The stations may be grouped into one way page groups The system also provides the ability for a remote speaker loca...

Page 2: ...attern Ring contact closure follows ring cycle Inhibit input Caller identification RS 232 serial printer port Control unit is internally powered battery backup compatible 1 VPB 260 per unit Override p...

Page 3: ...and the key is pressed twice Remote Signaling Closure follows ring pattern 250 mA max 24 VDC PAGE PRIORITY It is possible for multiple inputs to request an audio connection to a speaker at the same t...

Page 4: ...these tones Power Connections Use a cord set consisting of a minimum 18 AWG cord and grounding type attachment plug rated a minimum of 15A 250V The cord set should have the appropriate safety approval...

Page 5: ...1 R16 R79 R80 R81 R82 R115 Handsfree Speaker to Phone Level Handsfree Phone to Speaker Level Background M usic Level External Tone Source Level All Call A djust Volum e Attendant Level Override P ort...

Page 6: ...Emergency Enable C C Override Page Port Tip Override Page Port Ring Dry Priority Activate Dry Priority Activate Inhibit Inhibit Group 2 38 13 39 14 40 15 41 16 42 17 43 18 BK G G BK BK BR BR BK BK S S...

Page 7: ...28 3 W GR GR W BACKGROUND MUSIC CONNECTION P7 Connecting Block P7 Connecting Block Low Level Music Source 47 22 48 23 49 24 50 25 47 22 48 23 49 24 50 25 47 22 48 23 49 24 50 25 INA 21 INB 21 INA 22...

Page 8: ...32 7 34 9 Signal Out V 9927A 1 8 Com EXTERNAL TONE SOURCE USING A V 9927A NOTE External tone source requires dip switch settings to enable feature See Table 1 SW3 8 W SL SL W R O O R R BR BR R 947211...

Page 9: ...K BL BL BK T R NOTE Global all call page requires dip switches SW 3 4 SW 3 5 be set on each V 2924 control unit to enable feature Y O O Y Y BR BR Y Y O O Y Y BR BR Y Y O O Y Y BR BR Y 947211_3 DRW P7...

Page 10: ...1092 26 1 27 2 28 3 To Enable Feature strap must remain across pair when unit is powered CLOCK SYNC INPUT 45 20 Master Clock Y SL SL Y P7 Connecting Block Master Clock must make contact closure at 02...

Page 11: ...F or group page Ringback tone to Attendant HF and group page SW3 3 No 15 second privacy tone to HF speaker 15 second privacy tone to HF speaker SW3 4 Priority phone controls local V 2924 only Priority...

Page 12: ...essful Inhibit Allows the use of a single line phone A lead modified When the phone goes offhook all handsfree group and or all call pages are cancelled and the phone is connected to the attendant Ove...

Page 13: ...it Zone Access to Individual Stations Dial Code Function 101 124 Handsfree speakers Main board during hf to zone 121 122 123 or 124 Operate relay for longer of 2 5 seconds or duration of second press...

Page 14: ...defective device within the warranty period provided that 1 inspection by Valcom Inc indicates the validity of the claim 2 the defect is not the result of damage misuse or negligence after the origin...

Page 15: ...427 6000 for Valcom 24 hour Automated Support or visit our website at http www valcom com Valcom equipment is not field repairable Valcom Inc maintains service facilities in Roanoke VA Should repairs...

Page 16: ...h multiple V 2924 systems that require all call and or priority pages to be broadcast to all interconnected systems Global Priority Activate 42 17 Control pair for use with multiple V 2924 systems tha...

Reviews: