background image

VSP-V-2924

Issue 3

1

947211

V-2924

TALKBACK INTERCOM SYSTEM

EXPANDABLE 24/48/72/96 ZONE

CONTENTS

INTRODUCTION

            1, 2

SPECIFICATIONS

            2, 3

INSTALLATION

            3, 4

Precautionary Information

            3, 4

V-2924 Control/Connector Locations 

 5

Punchdown Block Connections

6

Attendant Port Connection

7

Background Music Connection

 7

Door Speaker/Call Switch Conn.

7

Inhibit Option

8

External Tone Source (ex.V-9927A)

8

SMDR Printer Port Cable

  8

Override Page Port

9

Global All Call Page

9

Global Priority Page

9

Zone Page Option

10

Clock Sync

10

Dipswitch Options

11

OPERATION

12,13

    V-2924 with V-2925 Expansion Unit

Remote Station Access (Call Button)

13

Attendant Station Dialing Plan

13,14

TROUBLESHOOTING CHART

14

LIMITED WARRANTY

14

TECHNICAL ASSISTANCE

15

GLOSSARY OF TERMS

16

The V-2924 Talkback Intercom System provides 24 stations with one-way, two-way, group call and all call pages.
Each station can be programmed for one-way or two-way communication.  The stations may be grouped into one-
way page groups.  The system also provides the ability for a remote speaker location equipped with a call button to
call the attendant location.  The attendant receives calling speaker identification when using a Caller ID equipped
telephone or a Caller ID display.

The V-2924 is compatible with standard 45 ohm speakers and one-way amplified speakers and can be accessed via a
single line phone, E-Key line port or PABX loop start trunk port.   An RS-232 port on the control unit provides a
connection for a serial printer for printout of system activity.

The V-2924 provides a background music input and is designed to automatically mute music during a page.  The
basic system also provides four (4) contact closures associated with the last 4 zones to allow for door strike plate
activation.  Multiple V-2924 control units can be interconnected to allow global all call and global priority pages for
up to six (6) V-2924 control units.

Summary of Contents for V-2924

Page 1: ...d all call pages Each station can be programmed for one way or two way communication The stations may be grouped into one way page groups The system also provides the ability for a remote speaker loca...

Page 2: ...attern Ring contact closure follows ring cycle Inhibit input Caller identification RS 232 serial printer port Control unit is internally powered battery backup compatible 1 VPB 260 per unit Override p...

Page 3: ...and the key is pressed twice Remote Signaling Closure follows ring pattern 250 mA max 24 VDC PAGE PRIORITY It is possible for multiple inputs to request an audio connection to a speaker at the same t...

Page 4: ...these tones Power Connections Use a cord set consisting of a minimum 18 AWG cord and grounding type attachment plug rated a minimum of 15A 250V The cord set should have the appropriate safety approval...

Page 5: ...1 R16 R79 R80 R81 R82 R115 Handsfree Speaker to Phone Level Handsfree Phone to Speaker Level Background M usic Level External Tone Source Level All Call A djust Volum e Attendant Level Override P ort...

Page 6: ...Emergency Enable C C Override Page Port Tip Override Page Port Ring Dry Priority Activate Dry Priority Activate Inhibit Inhibit Group 2 38 13 39 14 40 15 41 16 42 17 43 18 BK G G BK BK BR BR BK BK S S...

Page 7: ...28 3 W GR GR W BACKGROUND MUSIC CONNECTION P7 Connecting Block P7 Connecting Block Low Level Music Source 47 22 48 23 49 24 50 25 47 22 48 23 49 24 50 25 47 22 48 23 49 24 50 25 INA 21 INB 21 INA 22...

Page 8: ...32 7 34 9 Signal Out V 9927A 1 8 Com EXTERNAL TONE SOURCE USING A V 9927A NOTE External tone source requires dip switch settings to enable feature See Table 1 SW3 8 W SL SL W R O O R R BR BR R 947211...

Page 9: ...K BL BL BK T R NOTE Global all call page requires dip switches SW 3 4 SW 3 5 be set on each V 2924 control unit to enable feature Y O O Y Y BR BR Y Y O O Y Y BR BR Y Y O O Y Y BR BR Y 947211_3 DRW P7...

Page 10: ...1092 26 1 27 2 28 3 To Enable Feature strap must remain across pair when unit is powered CLOCK SYNC INPUT 45 20 Master Clock Y SL SL Y P7 Connecting Block Master Clock must make contact closure at 02...

Page 11: ...F or group page Ringback tone to Attendant HF and group page SW3 3 No 15 second privacy tone to HF speaker 15 second privacy tone to HF speaker SW3 4 Priority phone controls local V 2924 only Priority...

Page 12: ...essful Inhibit Allows the use of a single line phone A lead modified When the phone goes offhook all handsfree group and or all call pages are cancelled and the phone is connected to the attendant Ove...

Page 13: ...it Zone Access to Individual Stations Dial Code Function 101 124 Handsfree speakers Main board during hf to zone 121 122 123 or 124 Operate relay for longer of 2 5 seconds or duration of second press...

Page 14: ...defective device within the warranty period provided that 1 inspection by Valcom Inc indicates the validity of the claim 2 the defect is not the result of damage misuse or negligence after the origin...

Page 15: ...427 6000 for Valcom 24 hour Automated Support or visit our website at http www valcom com Valcom equipment is not field repairable Valcom Inc maintains service facilities in Roanoke VA Should repairs...

Page 16: ...h multiple V 2924 systems that require all call and or priority pages to be broadcast to all interconnected systems Global Priority Activate 42 17 Control pair for use with multiple V 2924 systems tha...