background image

4

947301

TABLE 1 - DIPSWITCH SETTINGS FOR DOOR UNLOCK CODES

DIGIT

SW1

SW2

SW3

SW4

1
2
3
4

ON

OFF

ON

OFF

OFF

ON
ON

OFF

OFF
OFF
OFF

ON

OFF
OFF
OFF
OFF

5
6
7
8

ON

OFF

ON

OFF

OFF

ON
ON

OFF

ON
ON
ON

OFF

OFF
OFF
OFF

ON

9
0
*
#

ON

OFF

ON

OFF

OFF

ON
ON

OFF

OFF
OFF
OFF

ON

ON
ON
ON
ON

A
B
C
D

ON

OFF

ON

OFF

OFF

ON
ON

OFF

ON
ON
ON

OFF

ON
ON
ON

OFF

TABLE 2:  TROUBLESHOOTING CHART

PROBLEM

ACTION

1.  No system operation - Power LED not lit.

2.  No system operation - Power LED is lit.

3.  No paging at speaker.

4.  Paging at speaker but no reply from speaker.

5.  No system ringing when the doorplate button
     is pressed.

6.  Door unlock relay does not operate.

7.  No ringback tone to speaker when door
     button is pressed.

1a.  Verify AC voltage is present at the  receptacle.
1b.  Check the fuse located on the bottom of the unit.
       If blown, replace with a 1 amp 250 VAC fuse.

2a.  Verify that screw terminal connectors are completely
       plugged into circuit board headers.
2b.  Refer to Figure 2 and verify all connections.

3a.  Check door plate speaker connections.
3b.  Refer to Figure 5 and adjust Phone to Speaker
       volume.

4a.  Refer to Figure 5 and adjust Speaker to Phone
       volume.

5a.  Refer to Figure 5 and check Ring ON/OFF switch.

6a.  Refer to Table 1 and verify dip switch settings.

7a.  Refer to Figure 5 and adjust ringback tone volume
       control.

Reviews: