Table 2 - Valcom Power Supplies

 

 

Part # 

Voltage 

Maximum 

Current 

Valcom  

Power  

Units 

VP-324D 

-24VDC 

300mA 

+6 

VP-624D 

-24VDC 

600mA 

+12 

VP-1124D 

-24VDC 

1.0 amp 

+20 

VP-2124D 

-24VDC 

2.0 amp 

+40 

VP-4124D 

-24VDC 

4.0 amp 

+80 

VP-6124 

-24VDC 

6.0 amp 

+120 

VP-12124 

-24VDC 

12.0 amp 

+240 

 

There are several cases when more than one 
power supply will be required: 

 

 

When the power required exceeds the 
maximum output of the power supplies 
available:  Add additional supplies as 
required. 

 

In large systems or systems with many one-
way horn speakers:  Locate separate power 
supplies near groups of speakers.  Refer to 
the Valcom Wire Gauge Guide for guidelines 
concerning maximum allowable distances 
for power runs. 

 

When the paging system is in several 
buildings, or on several floors of a single 
building:  Locate a power supply in each 
building, or on each floor, that contains 
equipment requiring power. 

 

Environment 

Control Units: 
 

Temperature: 

0 to +40°C 

 

Humidity: 

0-85% non-condensing 

 
Inside Speakers: 
 

Temperature: 

-20 to +55°C 

 

Humidity: 

0-95% non-condensing 

 
Horn Speakers: 
 

Temperature: 

-20 to +55°C 

 

Humidity: 

0-95% non-condensing 

E-Key, PABX, or Dedicated Single 
Line Telephone Set  

 

 

Additional

 

   Zones

 

(multi-zone

 

units only)

 

Talkback  Speakers

 

Power Supply

 

 (if required)

 

One or more dedicated

 

single line telephone(s)

 

Block Diagram for Loop Start Trunk Port And/Or Single Line

 

Telephone Access of a Valcom Talkback Page Control/Interface

 

Audio To Up To 40

 

VALCOM One-Way

 

Self Amplified

 

VALCOM

 

Talkback

 

Page

 

Control/Interface

 

T

 

R

 

Telephone

 

System C.O.

 

Loop Start

 

Trunk Port

 

-AND/OR-

 

FIGURE 2

 

 

To provide handsfree answerback paging on 
1A2, E-Key, or  PABX Systems, you will need a 
talkback control, talkback speakers, and (if 
required) a power supply.  
 
The speakers may be anyone of Valcom's 45 
Ohm Talkback Speakers.  In most cases, if the 
control unit requires a power supply, the 
VP-624B will be adequate.  Larger power 
supplies may be required if one-way speakers or 
horns are utilized. 
 
Access will be from a C.O. line key on E-Key 
Systems, from a loop start trunk port on PABXs, 
or from Tip and Ring on one or more dedicated 
single line sets.  A trunk circuit will be required 
on a PABX or E-Key system. 
 

Page Port Access 

In general, telephone system page ports are not 
capable of passing audio in both directions and, 
therefore, are suitable for one-way paging only.  
In the case of bi-directional page ports, contact 
Technical Support for assistance in choosing the 
appropriate talkback page control/interface. 

 

Station Level Paging 

Station level access to talkback paging systems 
may be accomplished 

in certain instances

 by 

utilizing the Valcom V-9940 Station Level Page 
Adapter.  Due to  
the nature of talkback paging with station level 
access from various C.O. lines or PABX/PBX 
stations, it is advisable to contact Technical 
Support prior to configuring your system.