Valcom Supervised Ceiling Speaker with Amplifier Installation Instructions Download Page 3

3

COVERAGE

The area covered by a ceiling speaker is determined

by the height of the ceiling.  If  ceiling height is 8',

the speaker will cover 256 sq. ft.  With a ceiling

height of 10 feet, the speaker will cover 400 sq. ft.  If

the ceiling is 20 feet high, the speaker will cover

1600 sq. ft.

Table 1 - Number of Speakers per Audio Run

TECHNICAL ASSISTANCE

When trouble is reported, verify there are no broken

connections.  Assistance in troubleshooting is

available from the factory.  Call (540) 427-3900 and

ask for Technical Support or call (540) 427-6000 for

Valcom 24- hour Automated Support.  

Valcom equipment is not field repairable.  Valcom,

Inc. maintains service facilities in Roanoke, VA. 

Should repairs be necessary, attach a tag to the unit

clearly stating company name, address, phone

number, contact person, and nature of the problem.

Send the unit to:

 

Valcom, Inc.

Repair & Return Dept. 

5614 Hollins Road

Roanoke, VA  24019-5056

TROUBLESHOOTING CHART

SYMPTOM

ACTION

 1. No audio from speaker.

 2. Low volume from speaker.

 3. Loud squeal (feedback).

 1a. Check that volume control is turned up (clockwise).

 1b. Using a lineman's test set check for the proper audio level on the Tip and Ring leads,

and if necessary also at the source.

 2a. Check that volume control is turned up.

 2b. Check voltage at the speaker assembly when in use, -18 to -24VDC required.

 2c. Using a lineman's test set, check for the proper audio level on Tip and Ring leads.  It is

possible that some low level audio will be heard with only one side of Tip and Ring 

connected.

 3a. Turn down (counter-clockwise) volume of the speaker.

 3b. Increase the distance between the telephone and speaker.

 3c. Install a noise canceling handset on the telephone in severe problem areas.

 3d. Add a V-9962 Digital Feedback Eliminator.

VALCOM LIMITED WARRANTY

Valcom, Inc. warrants its products to be free from defects in materials and workmanship under conditions of normal use and service
for a period of one year from the date of shipment.  The obligation under this warranty shall be limited to the replacement, repair or
refund of any such defective device within the warranty period, provided that:

1.

inspection by Valcom, Inc. indicates the validity of the claim,

2.

the defect is not the result of damage, misuse, or negligence after  the original shipment.

3.

the product has not been altered in any way or repaired by others and that factory sealed units are unopened (A service
charge plus parts and labor will be applied to units defaced or physically damaged),

4.

freight charges for the return of products to Valcom are prepaid,

5.

all units ‘out of warranty’ are subject to a service charge.  The service charge will cover minor repairs (Major repairs will
be subject to additional charges for parts and labor).

This warranty is in lieu of and excludes all other warranties, expressed or implied, and in no event shall Valcom, Inc. be
liable for any anticipated profits, consequential damages, loss of time or other losses incurred by the buyer in connection
with the purchase, operation, or use of the product.

This warranty specifically excludes damage incurred in shipment.  In the event a product is received in damaged condition, the
carrier should be notified immediately.  Claims for such damage should be filed with the carrier involved in accordance with the
F.O.B. point.

Headquarters:

In Canada

Valcom, Inc.

CMX Corporation

1111 Industry Avenue

35 Van Kirk Drive #11 and 12

Roanoke, VA 24013

Brampton, Ontario L7A1A5

Phone:  (540) 437-3900

Phone:  (905) 456-1072

FAX:  (540) 427-3517

FAX:  (905) 456-2269

Wire Run(Ft.)

22 AWG

24 AWG

100
200
400
800

1600

150
150
100

50
25

150
120

60
30
15