4
947170
Terminal
Description
1
Ground for ground start/common connection for Terminals 2-7.
2
Close a contact between this terminal and J2-1 to activate attendant access.
3
Close a contact between this terminal and J2-1 to active TONE 1 (siren).
4
Close a contact between this terminal and J2-1 to activate TONE 2 (chime).
5
Connect a jumper between this terminal and J2-1 to disable confirmation and
preannouncement tones.
6
Connect a jumper between this terminal and J2-1 to disable the preannouncement
tone.
7
Connect a jumper between this terminal and J2-1 to enable Loop Start Supervised
(LSS) mode. (You must also set the slide switch on the front panel to the GS/LSS
position).
8
Attendant input, + phase of balanced 600 Ohm input.
9
Attendant input, – phase of balanced 600 Ohm input.
10
Music input, + phase of balanced 100 K Ohm input.
11
Ground for optional shield termination of music input.
12
Music input, – phase of balanced 100K Ohm input.
13
Audio output to paging system, + phase of balanced output, 300 Ohm.
14
Ground for optional shield termination of output.
15
Audio output to paging system, – phase of balanced output, 300 Ohm.
16
Normally open contact (with J2-17) that may be used to activate paging equipment.
17
Normally open contact (with J2-16). Contact is closed when any input with priority
higher than music is present.
18
Night bell Input from key systems. Night bell is activated by any low voltage greater
than 10VAC/DC.
19
Common terminal for night bell input voltage.
20
Night bell input from ringer voltage.
Table 1.
PagePal
®
J2 Terminal Block Connector
Technical Manuals Online! - http://www.tech-man.com
Technical Manuals Online! - http://www.tech-man.com
firealarmresources.com