2
947795
VIP-A12DS Housing Assembly
VIP-A16DS Housing Assembly
MOUNTING/CONNECTIONS
A minimum of 18” (for the VIP-A12DS) or 24
”
(for the
VIP-A16DS) of network cable must extend from the
mounting location for connection to the RJ45 jack on
the Network Interface inside the clock housing.
A safety restraint cable (not included) is strongly
recommended to be installed in addition to the
mounting bracket attachment to the wall or ceiling.
Insert the cable through the back of the mounting
bracket, through the center support bracket, and out
the large center hole. Securely attach the end of the
safety restraint cable to one of the predrilled holes in
the center support bracket. The other end of the safety
restraint cable should be securely attached to the
building structure.
Remove the shipping screws holding the mounting
bracket to the clock housing. Insert the network cable
through the back of the mounting bracket, then attach
the bracket to a double gang outlet box using the four
inner holes on the mounting bracket. Use the four
outer mounting holes if attaching directly to a wall or
ceiling.
Align the clock housing over the mounting bracket
flange and secure the clock housing to the flange with
eight screws provided (four each side). Confirm the
two screws at the opposite end of the center support
bracket are firmly tightened.
The Network Interface unit attaches to the center
support bracket inside the housing. Align the center
cable hole and two screw holes in the Network
Interface mounting plate with the predrilled holes in the
hanging rod and attach using two screws (included).
Feed the network cable from the mounting bracket into
the clock housing. Be careful to not damage the RJ45
connector on the cable.
Connect the network cable to the RJ45 jack on the
Network Interface in the housing.
Attach one 5-pin female molex connector from the
Network Interface to the clock movement on the back
of the clock, then slide the clock onto the housing and
secure by tightening two screws on the housing.
Repeat this procedure for the other clock face.
Setup
Information specific to your application will need to be
programmed into the VIP-A1xDS using a computer.
The PC used for programming should be connected to
the same subnet as the VIP-A1xDS. Setup will be
done using the IP Solutions Setup Tool. Download the
latest version of the free IP Solutions Setup Tool from
the Valcom.com web site at
www.valcom.com/vipsetuptool.
TECHNICAL ASSISTANCE
When trouble is reported, verify power is being
supplied to the unit and there are no broken
connections. If a spare unit is available, substitute a
spare unit for the suspected defective unit.
Assistance in troubleshooting is available from the
factory. Call (540) 563-2000 and press 1 for Technical
Support or via email at [email protected]
When requesting assistance, you should include all
available information. It is strongly suggested that you
go to the web site and review the documentation at:
http://www.valcom.com.
Valcom equipment is not field-repairable. Valcom, Inc.
maintains service facilities in Roanoke, VA. Should
repairs be necessary, attach a tag to the unit clearly
stating your company name, address, phone number,
contact person and the nature of the problem.
Send the unit to:
Valcom, Inc.
Repair & Return Dept.
5614 Hollins Road
Roanoke, Va. 24019-5056
Network
Connection