Mounting 

The VIP-432-DF is designed for flush mounting on 
a hollow surface or to a Valcom backbox.  Using the 
dimensions shown in Figure 2 as a guide, cut a hole 
in the mounting surface large enough to allow 
recessing the VIP-432-DF into the wall.  Next, drill 
mounting holes in the surface to align with the four 
mounting holes in the grille.  Using appropriate 
anchors and screws (not included), mount the     
VIP-432-DF to the surface.  Alternatively, Valcom 
backbox model VB-R19 is available for mounting 
this model. 

 

Network Connection 

The VIP-432-DF has one  RJ-45 network connector 
on the rear panel.  Use the standard Ethernet  
patch cable and connect the VIP-432-DF to an 
Ethernet switch. (See Figure 1) 
 

Call Switch Connection 

The VIP-432-DF provides a call switch input via 
screw terminal connections. (See Figure 1) 
 

Mute Out Connection 

The Mute Out may optionally be connected to the 
mute input of Valcom Classroom audio 
management systems in order to suspend locally 
originated classroom audio during intercom 
announcements. 

 
LED Connection

  

LED (+) and (-) is a current limited output designed 
to illuminate an optional LED. The LED is intended 
to provide visual indication of call progress.  The 
LED illumination will flash when the call switch is 
pressed and will continue to flash until the call is 
answered.  The LED illumination will be solid when 
a connection to the unit is established. 
 
 
 

-10 dB Line Level Out Connection 

The -10dBm Line Level Out may be connected to 
up to 40 Valcom Self Amplified Speakers in order to 
provide additional sound reinforcement in an area. 
 

Setup 

Information specific to your application will need 
to be programmed into the VIP-432-DF using a 
computer.  The PC used for programming should 
be connected to the same subnet as the            
VIP-432-DF.  Setup will be done using the IP 
Solutions Setup Tool.  The IP Solutions Setup Tool 
may be downloaded from the Valcom website at 
www.valcom.com/vipsetuptool. 
         

TECHNICAL ASSISTANCE 

When trouble is reported, verify power is being 
supplied to the unit and there are no broken 
connections.  If a spare unit is available, substitute 
a spare unit for the suspected defective unit. 

 

Assistance in troubleshooting is available from the 
factory.  Call (540) 563-2000 and press 1 for 
Technical Support or via email at 
[email protected] 

 

When requesting assistance, you should include all 
available information.  It is strongly suggested that 
you go to the web site and review the information 
available at http://www.valcom.com. 

 

Valcom equipment is not field repairable.  Valcom, 
Inc. maintains service facilities in Roanoke, VA.  
Should repairs be necessary, attach a tag to the 
unit clearly stating your company name, address, 
phone number, contact person and the nature of 
the problem. Send the unit to: 

 

Valcom, Inc. 

Repair & Return Dept. 

5614 Hollins Road 

Roanoke, Va. 24019-5056 

Figure 1. Connections 