Figure 34 Operating Supply Power Consumption
More Information
‣
SLEEP — Enter Low-Power Mode (page 127)
4.10.2 Heating Power
The following table shows the minimum power supply requirements of the WMT700 heating
options.
In maritime environments, the normal input voltage ranges are: operating voltage
10 … 30 VDC (-10% … +30%) and heating voltage 24 … 30 VDC (-10% … +30%), as defined
in the maritime standard IEC 60945.
Table 29 Heating Power Supply Requirements
Heating Option
Heating Voltage
Required Heating Power
Supply
None
-
-
Transducers
24 … 36 VDC
40 W
Transducers and arms
24 … 36 VDC
200 W
Transducers, arms and body
24 VDC
350 W (2 m cable)
Chapter 4 – Installation
79