a
WMT700 address. If the value is
0
, it refers to any WMT700 address
WMT700 automatically returns to normal operating mode, if it does not receive
commands in two minutes, or if it detects multiple unrecognized commands.
5.11.1.3 POLL — Poll Data
This command fetches data from WMT700. You need to specify the data message number in
the polling command.
When WMT700 is in the low-power mode, it does not receive the first character in the
command. You must send an extra character (space) before the polling command to
receive data.
$aPOLL,y<CR><LF>
$
Fixed text
a
WMT700 address. If the value is
0
, it refers to any WMT700 address.
y
Identification number for the data message format.
Example
In this example WMT700 custom data message 1 is polled from WMT700.
$0POLL,1<CR><LF>
More Information
‣
5.11.1.4 SLEEP — Enter Low-Power Mode
This command switches WMT700 from the normal operating mode to the low-power mode.
WMT700 resumes normal operation after sleep period determined by the
sleepTime
parameter has elapsed, or when a character is received on data port COM2. For more
information on the
sleepTime
parameter.
$aSLEEP<CR><LF>
Chapter 5 – Operation
127
Summary of Contents for WINDCAP WMT700 Series
Page 1: ...M211095EN H User Guide Vaisala WINDCAP Ultrasonic Wind Sensor Series WMT700 ...
Page 32: ...WMT700 User Guide M211095EN H 30 ...
Page 100: ...WMT700 User Guide M211095EN H 98 ...
Page 168: ...4 Remove the verifier WMT700 User Guide M211095EN H 166 ...
Page 174: ...WMT700 User Guide M211095EN H 172 ...
Page 182: ...WMT700 User Guide M211095EN H 180 ...
Page 194: ...WMT700 User Guide M211095EN H 192 ...
Page 198: ...WMT700 User Guide M211095EN H 196 ...
Page 201: ...Appendix G Certificate Appendix G Certificate 199 ...
Page 202: ...WMT700 User Guide M211095EN H 200 ...
Page 208: ...WMT700 User Guide M211095EN H 206 ...
Page 209: ......
Page 210: ...www vaisala com ...