6. Technical data
6.1 WAT12 specifications
Table 10 Operating environment
Property
Description/Value
Operating temperature
–55 ... +55 °C (-67 ... +131 °F)
Storage temperature
–60 ... +70 °C (-76 ... +158 °F)
Operating humidity
0 ... 100 %RH
Table 11 Inputs and outputs
Property
Description/Value
Input operating power
12 ... 28 VDC, 30 mA
Output sensor power
On-board regulated to 10.7 VDC typically
Signal input from sensors
Wind direction
6-bit parallel GRAY code (optionally 7 bits)
Wind speed
Pulse frequency 0 ... 750 Hz
Output signals
2 analog current loops
1 for direction, 1 for speed
Highside drivers; the loops return to the common signal and power ground
Typical loop driving voltage
10 V
Output accuracy
> 1 % of full scale
Loop current options (jumper selectable)
0 ... 5 mA
1 ... 5 mA
0 ... 10 mA
2 ... 10 mA
0 ... 20 mA
4 ... 20 mA
Max. loop resistance (including cable resistance
and receiver's input resistance)
5 mA loop: 1800 Ω
10 mA loop: 900 Ω
20 mA loop: 450 Ω
WAT12 User Guide
M210309EN-B
30