Vaisala WAC151 Technical Reference Download Page 6

 

Cross Arm WAC151 

WAC151-T648en-1.1 

Technical Reference 

1996-09-25 

1. 

INTRODUCTION 

 

 

 

The  WAC151  is  a  cross  arm  assembly  to  support  the  Vaisala  WAA151 
Anemometer,  WAA251  Heated  Anemometer  and  WAV151  Wind  Vane.  The 
assembly consists of an anodized aluminum tube construction with a mounting 
clamp for installation on top of a mast. 

A  water  tight  junction  box  is  fitted  to  the  cross  arm,  including  a  screw 
terminal  block  for  connection  of  the  power  and  signal  cables.  Inside  the 
junction  box,  there  is  also  a  thermostat  switch  for  controlling  sensor  shaft 
heating for the standard '151-series sensors. 

The  junction  box  is  equipped  with  four  cable  glands  offering  easy  way  for 
earthing  different  cables.  Typically,  three  cable  glands  are  in  use;  two  for 
sensor  cables  one  for  signal  cables.  To  ensure  accurate  wind  speed 
measurement  in  extreme  winter  conditions,  WAA251  Heated Anemometer as 
well  as  WHP25  Outdoor  Mains  Power  Supply  are  recommended.  The  fourth 
gland  is  reserved  for  the  cable  supplying  heating  power  for  heated 
anemometer system. 

It is important to notice that wiring instruction label inside the junction box is 
for  the  standard  '151-series  sensors.  However,  when  WAC151  is  used  with 
WAA251  Heated  Anemometer,  small  wiring  changes  are  necessary.  Please, 
refer to the drawing WA35172. 

The  cross  arm  is  installed  in  the  north-south  direction,  with  the  wind  vane 
pointing to the north. The cross arm supports just one way to fix the sensors to 
it ensuring correct assemblage. 

Summary of Contents for WAC151

Page 1: ......

Page 2: ...CROSS ARM WAC151 Technical Reference WAC151 T648en 1 1 25 September 1996 Vaisala 1996...

Page 3: ...y form or by any means electronic or mechanical including photocopying nor may its contents be communicated to a third party without prior written permission of the copyright holder The contents of in...

Page 4: ...Cross Arm WAC151 WAC151 T648en 1 1 Technical Reference 1996 09 25 i Contents 1 INTRODUCTION 1 2 INSTALLATION 2 3 TECHNICAL DATA 3 4 APPENDICES DRAWINGS 4...

Page 5: ...Cross Arm WAC151 Technical Reference WAC151 T648en 1 1 ii 1996 09 25 This page intentionally left blank...

Page 6: ...able glands offering easy way for earthing different cables Typically three cable glands are in use two for sensor cables one for signal cables To ensure accurate wind speed measurement in extreme win...

Page 7: ...cables through the cable glands s For better protection against RF interference follow the earthing instructions of the cable shield in drawing WA35095 3 Do the wiring to the screw terminal block acco...

Page 8: ...m supports the WAA151 WAA251 and WAV151 sensors Material Cross Arm Al anodized Junction Box Al painted Weight 1 5 kg without sensors Electrical connections Cable entries Line cable entry through a gla...

Page 9: ...ence WAC151 T648en 1 1 4 1996 09 25 4 APPENDICES DRAWINGS WA35095 WAC151 Cross Arm Assembly ZZ45037 Sensor Wind Vane Cable Assembly ZZ45036 Sensor Anemometer Cable Assembly WA35172 WAT11 Wind Sensor C...

Reviews: