8.
When prompted for the port, type the port to which the sensor is connected. For example:
Serial port name [COM0]: COM3
Command Prompt lists the files that are in the directory.
9.
Select the firmware file using the number indicated in the beginning of the row. For example:
Potential images in working directory:
[1] 1.1.0 MD30_Customer_release_1.1.0.fw
Select a number or '0' for other files:
>
> 1
The update takes a couple of minutes, depending on the port speed.
10. When this message is displayed, press
ENTER
. The software update is done.
Running OK
Current SW version: [version]
Press ENTER to exit
11.
Disconnect the wires from the screw terminal, and connect the 8-m (26-ft) extension cable back
to your data collection system.
For instructions, see
Vaisala Mobile Detector MD30 Setup Guide
.
Quick Guide
M212537EN-A
7