HMD60U/Y Transmitters
Operating Manual
U301en-1.1
10
1997-07-31
6.3
General
Supply voltage
10...35 VDC (RL= 0
Ω
)
20...35 VDC (RL=500
Ω
)
Output signal
4...20 mA
Operating temperature range:
electronics
-5...+55
°
C
sensor head
-40...+80
°
C
Storage temperature range
-40...+80
°
C
Housing:
sensor head
stainless steel
electronics housing
cast aluminium
Cable lead-through:
bushing
for 7...10 mm (PG9) cable
(housing IP65 / NEMA 4),
part no. 18941HM
or armoured cable glands
part no. 10528HM
Sensor protection:
standard
membrane filter
(part no. 17039HM)
option
stainless steel sintered filter
(part no. HM46670)
Connections
screw terminals 0.5...1.5 mm2
Summary of Contents for Humicap HMD60Y
Page 1: ...USER S GUIDE Vaisala HUMICAP Humidity and Temperature Transmitters HMD60U Y U301EN11...