background image

Legacy configuration codes                                                                                  

Valid from 25th February 2003

HMP234 Humidity and Temperature Transmitter

With pressure tight high temperature probe

Industrial humidity and temperature transmitter

HMP234

1

A

PRICE

Transmitter

RH+T

A

type

RH+T+Td

B

RH+T+a+Tw+x

C

RH+T+Td+a+Tw+x+h

D

RH+T+h

F

Display

no display

1

display on transmitter cover

2

Probe cable length

2 m cable, +180 °C (+356 °F)

A

5 m cable, +180 °C

(+356 °F)

B

10 m cable, +180 °C (+356 °F)

C

Power supply,

24 V, no connectors

0

alarm output &

115 V, no connectors

1

connectors

230 V, no connectors

2

24 V, + alarm output unit (no connectors)

3

24 V, shared connector for power supply and analog outputs

4

24 V, as above + alarm output unit not on connector

5

115 V, connector for analog outputs

6

230 V, connector for analog outputs

7

Using serial interface:

24 V, connector for RS232C

8

24 V, 2 connectors: RS232C and analog power supply

9

24 V, 2 connectors shared for power supply and RS485

9

Serial interface

RS 232C

A

RS 485/RS 422

B

current loop

C

Sensor protection

sintered stainless steel filter (16452)

1

Analog output

4...20 mA

A

A

signals

0...20 mA

B

B

(Ch1 and Ch2)

0...1 V

C

C

0...5 V

D

D

0...10 V

E

E

channel 1
channel 2

Parameters for the

RH

(0...100 %RH)

1

1

analog outputs

T

(range: see below)

2

2

(Ch1 and Ch2)

Td

(-40...+100 °C)

(-40...+212 °F)

3

3

a

(0...600 g/m3)

(0...+262 gr/ft3)

4

4

Tw

(0...+100 °C)

(+32...+212 °F)

5

5

x

(0...500 g/kg d.a.)

(0...3500 gr/lb d.a.)

6

6

h

(-40...1500 kJ/kg)

(-17.2...644.9 Btu/lb)

7

7

channel 1
channel 2

Analog output range -20...+80 °C

(-4...+176 °F)

A

for temperature

-20...+120 °C

(-4...+248 °F)

B

-20...+180 °C

(-4...+356 °F)

C

-40...+80 °C

(-40...+176 °F)

D

-40...+120 °C

(-40...+248 °F)

E

-40...+180 °C

(-40...+356 °F)

F

Units (local display

metric

1

and serial interface)

non-metric

2

A

Regaining option *)

no regaining

(HUMICAP K)

3

and sensor type

regaining

(HUMICAP KC)

2

Manual language

No manual

A

English

B

German

C

French

D

Finnish

E

TOTAL

*) Humidity sensor regaining can be used to reduce the effects of some chemical contaminants.

QTY

Please note that if mains power (115/230V) is selected regaining cannot be used.
For further information about this option, please see product data sheet or contact Your Vaisala representative.

TOTAL VALUE

Selections in bold are included in the prices of the basic versions.
Selections in italic are available at an extra price.

Example of order code with typical settings:

HMP234 A

1

A

0

A

1

A

A

1

2

A

1

A

3

B

End customer: