Element Name
Description
Priority
(Optional) Displays the priority of the alarm if the system has priority classification
capability.
Type
The type of the event message. See
Events Panel Tabs/Event Types (page 51)
Device
The sensor, or other piece of equipment, that the event is related to.
Site
The measurement site or other logical entity that the message is related to.
Server
The server that the message is related to.
Message
The actual message text, for example, a description of the problem and the name
of the problem sensor.
This button marks the selected event as acknowledged. The system stores the
event in a history file, together with the time of acknowledgement. The
Status
column stays red until an
OVER
event for the same reason happens.
If the system includes the optional sound alarm, clicking this button will turn off
the alarm sound for the current alarms. A new alarm event will activate the sound
alarm again.
This button does not acknowledge the alarm.
6.3 Operating Diagnostics Application
6.3.1 Starting and Exiting Diagnostics
Depending on your user profile and system configuration, the application may start
automatically when you log in to an AviMet workstation, or you can open it using the
corresponding shortcut icon, for example, in the desktop.
If your system includes the optional sound alarm and you minimize the
Diagnostic application, make sure that the volume is ON so that you will be able to hear
the sound alarms when they occur.
CAUTION!
Do not close the application unless you have a special reason, such as
system maintenance.
CAUTION!
6.3.2 Monitoring and Acknowledging Events
The
Events
panel displays all the system events configured to be displayed for your user
group. Depending on the configuration, the events typically appear on several tabs, for
example, in accordance with event type.
Low-Level Windshear Alert System User Guide
M210885EN-K
52
Summary of Contents for CT25K
Page 1: ...M210885EN K User Guide Vaisala AviMet â Low Level Windshear Alert System ...
Page 5: ...Glossary 73 Index 77 Technical Support 81 Warranty 81 Recycling 81 Table of Contents 3 ...
Page 8: ...Low Level Windshear Alert System User Guide M210885EN K 6 ...
Page 44: ...Low Level Windshear Alert System User Guide M210885EN K 42 ...
Page 68: ...Low Level Windshear Alert System User Guide M210885EN K 66 ...
Page 82: ...Low Level Windshear Alert System User Guide M210885EN K 80 ...
Page 84: ...Low Level Windshear Alert System User Guide M210885EN K 82 ...
Page 85: ......
Page 86: ...www vaisala com ...