Appendix
0020239015_05 ecoTEC plus Installation and maintenance instructions
43
VU 246/6-5 OVZ (P-GB)
Flue gas temperature (50 °C/30 °C)
at P max.
60
℃
Flue gas temperature (50 °C/30 °C)
at P min.
35
℃
Flue gas temperature in hot water
handling mode
68
℃
Flue gas temperature when over-
heating
95
℃
Released system types
C13
Nominal efficiency at 80/60 °C
98.2 %
Nominal efficiency at 50/30 °C
102.0 %
Nominal efficiency at 40/30 °C
104.0 %
Product dimensions, width
375 mm
Product dimensions, depth
295 mm
Product dimensions, height
602 mm
Net weight
23 kg
Weight when filled with water
28 kg
Technical data
–
Electrics
VU 246/6-5 OVZ (P-GB)
Electric connection
230 V / 50 Hz
Built-in fuse (slow-blow)
T2/2A, 250V
Max. electrical power consump-
tion
29 W
Standby electrical power con-
sumption
2 W
Level of protection
IPX4D