4.7 User
screens
(examples)
4.7.1
Entering time programmes (example for
heating)
Using the time programmes you can set up to three time
windows per weekday or block of days (e.g. Mo - Fr). In
these time windows, the heating control system provides
the room temperature you have entered, the so-called
comfort temperature. Outside the time windows the
room temperature is set back. You can also set this set-
back temperature.
h
Note!
If you programme the control to match your
lifestyle in the most optimum manner then you
will save energy whilst maintaining heating
comfort.
The way to set the time windows is shown in the
following example for the heating circuit. Time windows
can be set in the same way for the hot water preparation
and for a circulation pump.
⇒
Turn the left-hand dial further until the screen 2,
HC1 is displayed.
1
> Select day of week
21.5 °C
HC1
2
Mo
2
Time programme
3
06 : 00 - 10 : 40
: - :
: - :
Fig. 4.13 Screen 2 (example)
⇒
Turn the right-hand dial until the cursor
is in front
of the input field for the weekday or block of days.
⇒
Click the right-hand dial.
The field is highlighted.
⇒
Select the desired weekday or block of days by
turning the right-hand dial. The options are:
– Mo, Tu, .. etc.
– Mo - Fr (Block)
– Sa - Su (Block)
– Mo - Su (Block)
⇒
Confirm the selection by clicking with the right-hand
dial.
1, 2 and 3 in the display signify the "time window" that
you can set for the selected weekday or block of days.
Within a time window (e.g. from 06:00 to 10:40) the
VRT 392 provides heating in accordance with the
associated comfort temperature (e.g. 21.5 °C).
⇒
Turn the right-hand dial until the cursor
is located
in front of the input field for the start time of time
window 1.
⇒
Click the right-hand dial.
The field is highlighted.
⇒
Select the desired start time by turning the right-
hand dial.
Per step of the dial the time changes by 10 minutes.
⇒
When the desired start time is displayed confirm by
clicking with the right-hand dial.
The time for the end of the time window 1 should be set
accordingly.
The desired comfort temperature for the time window 1
is set as follows:
⇒
Turn the right-hand dial until the cursor
is located
in front of the input field for the comfort
temperature in time window 1.
⇒
Click the right-hand dial.
The field is highlighted.
⇒
Select the desired comfort temperature by turning
the right-hand dial (one step corresponds to a
change of 0.5 °C).
⇒
When the desired comfort temperature is displayed,
confirm by clicking with the right-hand dial.
h
Note!
The control supports the user when
programming time windows:
a) The programmed times can only be
chronological.
b) A programmed time window cannot overlap
an earlier time window.
A time window can only be located between
0:00 and 24:00.
An existing time window can be deleted
as follows:
Set the start time and the end of a window to
the same time.