![Vaillant VIH R 300/3 BR Safety Instructions Download Page 10](http://html.mh-extra.com/html/vaillant/vih-r-300-3-br/vih-r-300-3-br_safety-instructions_848757010.webp)
Appendix
8
Safety
instructions
0020241666_01
C
Technical data
Technical data
–
VIH R/RW general
VIH R 300/3
BR
VIH R 400/3
BR
VIH R 500/3
BR
VIH R 300/3
MR
VIH R 400/3
MR
VIH R 500/3
MR
Nominal capacity
294 l
398 l
490 l
294 l
398 l
490 l
Domestic hot water capacity
of the heating coil for the
heating circuit
9.9 l
10.9 l
15.2 l
9.9 l
10.9 l
15.2 l
Maximum pressure of the
heating coil during operation
1 MPa
1 MPa
1 MPa
1 MPa
1 MPa
1 MPa
Operating pressure
1 MPa
1 MPa
1 MPa
1 MPa
1 MPa
1 MPa
Maximum temperature of the
heating circuit
110
℃
110
℃
110
℃
110
℃
110
℃
110
℃
Maximum hot water temper-
ature
85
℃
85
℃
85
℃
85
℃
85
℃
85
℃
Energy efficiency class
B
B
B
A
A
A
Standby energy consumption
per 24 hrs
1.40 kWh
1.52 kWh
1.78 kWh
1.16 kWh
1.22 kWh
1.31 kWh
Heating coil pressure loss
(heating circuit)
0.0058 MPa
0.0066 MPa
0.00162 MPa
0.0058 MPa
0.0066 MPa
0.00162 MPa
Heating coil surface (heating
circuit)
1.5 m
²
1.7 m
²
2.3 m
²
1.5 m
²
1.7 m
²
2.3 m
²
Volume of domestic hot wa-
ter at 40 C (V
₄₀
) (heating cir-
cuit)
473 l
578 l
742 l
473 l
578 l
742 l
Net weight
103 kg
136 kg
170 kg
115 kg
149 kg
186 kg
Weight filled ready for opera-
tion
397 kg
535 kg
661 kg
409 kg
548 kg
677 kg
VIH RW 300/3
BR
VIH RW 400/3
BR
VIH RW 500/3
BR
VIH RW 300/3
MR
VIH RW 400/3
MR
VIH RW 500/3
MR
Nominal capacity
281 l
375 l
460 l
281 l
375 l
460 l
Domestic hot water capacity
of the heating coil for the
heating circuit
20.4 l
28.9 l
38.6 l
20.4 l
28.9 l
38.6 l
Maximum pressure of the
heating coil during operation
1 MPa
1 MPa
1 MPa
1 MPa
1 MPa
1 MPa
Operating pressure
1 MPa
1 MPa
1 MPa
1 MPa
1 MPa
1 MPa
Maximum temperature of the
heating circuit
110
℃
110
℃
110
℃
110
℃
110
℃
110
℃
Maximum hot water temper-
ature
85
℃
85
℃
85
℃
85
℃
85
℃
85
℃
Energy efficiency class
B
B
B
A
A
A
Standby energy consumption
per 24 hrs
1.40 kWh
1.54 kWh
1.84 kWh
1.05 kWh
1.16 kWh
1.04 kWh
Heating coil pressure loss
(heating circuit)
0.00106 MPa
0.0056 MPa
0.00117 MPa
0.00106 MPa
0.0056 MPa
0.00117 MPa
Heating coil surface (heating
circuit)
3.1 m
²
4.4 m
²
5.9 m
²
3.1 m
²
4.4 m
²
5.9 m
²
Volume of domestic hot wa-
ter at 40 C (V
₄₀
) (heating cir-
cuit)
423 l
577 l
710 l
423 l
577 l
710 l
Net weight
141 kg
181 kg
235 kg
153 kg
195 kg
251 kg
Weight filled ready for opera-
tion
422 kg
556 kg
694 kg
434 kg
570 kg
710 kg
Summary of Contents for VIH R 300/3 BR