7
Installation instructions for VED electric instantaneous water heater 0020149586_00
No. Quantity Name
1
1
VED electric instantaneous water heater
2
1
Operating and installation instructions
3
1
Box containing fixings (2 bolts, 2 rawl plugs,
1 seal, 1 special fixing screw)
4
1
Cold water connection piece R 1/2 with a cold
water stop valve
5
1
Hot water connection piece R 1/2 supplied in the
box
6
1
Installation plate
7
1
Installation template
Tab. 4.1 Scope of delivery
The VED electric instantaneous water heater is com-
pletely pre-assembled. Once the unit has been fitted to
the wall, only the water and electrical installation needs
to be completed.
4.2 Installation
site
b
Caution.
Risk of frost damage to the unit.
If a VED electric instantaneous water heater
is placed out of operation for a relatively long
period of time in an unheated room in cold
weather, the water in the unit and pipes may
freeze. This results in damage to the unit.
>
Install the unit in a permanently frost-free
room.
i
The VED electric instantaneous water heater
meets the current safety regulations for pro-
tected zone 1 and can therefore also be
installed above the bath or in a shower area.
>
Wherever possible, install the unit near the draw-off
point that will be most used.
4.3
Required minimum clearances
D
C
E
A
C
B
B
Fig. 4.2 Installation clearances
Key
A At least 50 mm
B At least 50 mm
C At least 120 mm
D At least 130 mm
E Maximum 22 mm
The bottom section of the unit (
D
) must be level with the
unit's bearing area on the wall; to a height of at least
130 mm. Any possible wall offset (e.g. due to tiles) must
not exceed 22 mm (
E
). The distance to the floor must be
at least 120 mm (
C
). The distance above, to the left and
to the right of the unit must be at least 50 mm.
Installation 4
Summary of Contents for VED
Page 1: ...Operating and installation instructions EXP VED ...
Page 2: ......
Page 3: ...For the operator Instructions for use VED Electric instantaneous water heater ...
Page 9: ...VED Electric instantaneous water heater For the competent person Installation instructions ...
Page 26: ......
Page 27: ......
Page 28: ...0020149586_00 EXPen 072012 Subject to change Manufacturer ...