OPERATION

Check the water contents

Check the water contents of the
system on the pressure gauge (

1

).

The needle on the pressure gauge
should be within the green band
(between 1 and 1.5 bar). If the
needle displays a value below 
0.8 bar when the appliance is
cold, follow the instructions left by
your installer to refill the system.
Alternatively, your installer should
be called to refill the system.

VRC-VC

C

o

0

I

C

o

1

Fig. B.4: Checking the water level 

Euro B/S 076/1

C

o

0

I

C

o

VRC-VC

C

o

C

o

2

3

Fig. B.5: Domestic hot water supply

Euro B/S 077/1

Domestic hot water 
operation (TURBOmax
Plus only)

The boiler should only be used
when the heating system con-
tains water. Use of the boiler
without water may cause
damage to the boiler or its
components. 

Setting the maximum domestic
hot water temperature control

Turn the main switch (

2

) to the „

l

position.

The display will show the boiler
flow temperature which indicates
electrical power to the boiler.

The domestic hot water tempera-
ture can be adjusted using the hot
water temperature control (

3

).

Turn the control clockwise to increa-
se the temperature and anti-clock-
wise to decrease the temperature.

As a guide for normal circumstances
set the knob to the one o´clock positi-
on.

Note: 

This control adjusts the maximum
domestic hot water temperature. If
adjusting the control upwards
appears to have no effect on the
temperature, then the boiler is
already operating at full output for
the selected flow rate.

If you live in a hard water
area please do not set the
control knob above the mid
(12 o´clock) position to prevent
excessiv scale formation 
(fig. B.5).

Summary of Contents for TURBOmax Plus 824/2 E

Page 1: ...INSTRUCTIONS FOR USE TURBOmax Plus 824 2 E 828 2 E THERMOcompact 615 2 E 620 2 E 624 2 E 628 2 E The code of practice for the installation commissioning servicing of central heating systems...

Page 2: ...arnings 6 Factory Guarantee 7 Operation Overview 8 Initial checks before turning ON 9 Domestic hot water operation TURBOmax Plus only 10 Heating operation 13 Resetting the appliance 14 Turning the boi...

Page 3: ...to provide domestic hot water whenever a hot water tap is opened and auto matically adjusts to meet the demand for both central heating and domestic hot water in the most economical way THERMOcompact...

Page 4: ...fica tions and official safety regulations These appliances are designed as boilers for use in central heating and hot water supply systems THERMOcompact boilers only supply domestic hot water where a...

Page 5: ...compartment for storage purposes Gas smell If you smell gas or suspect a gas leak Turn off the boiler Do not switch any electrical switches in the hazardous area ON or OFF Do not smoke in the hazardou...

Page 6: ...store any explosive or highly flammable materials e g gasoline paper or paint near to the appliance Inspection The boiler should be serviced annually We recommend that you sign a service agreement wit...

Page 7: ...n Card and return to Vaillant within 30 days of installation Your details will then be automatically registered within the Vaillant scheme Note No receipt will be issued Immediate help If your Vaillan...

Page 8: ...rent operating mode 8 Reset button see page 14 9 Maximum hot water temperature control and warmstart ON OFF control page 11 10Pressure gauge displaying the pressure in the heating system THERMOcompact...

Page 9: ...o B S 009 0GB picture shows a TURBOmax Plus boiler Indicator lights boiler display TURBOmax Plus and THERMOcompact boilers have an advanced multi function boiler display 1 When the main ON OFF control...

Page 10: ...may cause damage to the boiler or its components Setting the maximum domestic hot water temperature control Turn the main switch 2 to the l position The display will show the boiler flow temperature...

Page 11: ...for a short time The green indicator light will now illuminate Reset the hot water temperature control knob to the desired setting The boiler will now provide instantaneous delivery of hot water direc...

Page 12: ...g a hot water tap 1 at a supply point basin shower bath etc the TURBOmax PLus boiler will automatically operate to deliver hot water On closing the tap the boiler switches OFF or continues to operate...

Page 13: ...mperature of the water within the boiler circuit After the boiler stops operating the pump and fan will continue to operate for a short period to fully disperse the heat from the boiler Note The boile...

Page 14: ...performed after pressing the Reset button Press the Reset button 2 and hold for approx 1 second If the boiler still shuts off after a third attempt then please consult your installer or Vaillant Serv...

Page 15: ...o 0 I C o C o C o I 0 2 Fig B 13 Shutting down the unit completely Euro B S 124 1 VRC VC C o 0 I C o C o C o C o 1 Fig B 12 Setting the summer operating mode Euro B S 123 1 To turn OFF central heating...

Page 16: ...stem unless there is no demand for domestic hot water VRC VC 0 I C o C o I 0 2 THERMOcompact Fig B 15 Shutting down the unit completely Euro B S_VC_088 1 VRC VC 0 I C o C o C o 1 THERMOcompact Fig B 1...

Page 17: ...vicing it is strongly recommended that arrangements are made with your service agent or Vaillant Ltd For further details please contact Vaillant Service Solutions 0870 6060777 Frost protection Your bo...

Page 18: ...staller or service agent during service and maintenance work 2 1 VRC VC C o 0 I C o Fig B 16 Status displays Table B 1 Status displays A complete overview of the status codes can be found in the insta...

Page 19: ...19...

Page 20: ...2001 M Printed on 100 recycled paper Subject to alteration Head Office Vaillant Ltd Vaillant House Medway City Estate Trident Close Rochester Kent ME2 4EZ Service Solutions 0870 6060 777 Technical Ad...

Reviews: