background image

4 Operation

8

Operating instructions HOME 0020224339_00

Symbol

Meaning

/

Fault in the product

Appears instead of the
basic display.

OFF

Appears when switching
the product to standby
mode.

3.4.2 Description of button

functions

Button

Meaning

Selecting the operating mode

Confirm the operating mode

Confirm setting

Increase the display contrast

or

Setting the hot water temperat-
ure

Setting the heating flow tem-
perature

Increase or decrease the selec-
ted setting

Increase the display contrast

Activate the product: On/off
(standby)

Reset the product

Adjustable values flash on the display.
You must confirm any change to a value.
Only then is the new setting saved.
If you do not press any buttons for five
seconds, the displays switches back to
the basic display.
If you do not press any buttons for one
minute, the display contrast decreases.

3.5 Operating levels

The product has two operating levels.

Operator operating level: This provides
access to the most important informa-
tion and setting options that do not re-
quire any particular prior knowledge.

Operating level for competent persons
only: This is protected by an access
code.

4 Operation

4.1 Starting up the product
4.1.1 Opening the isolator devices

1. Ask the competent person who in-

stalled the product to explain to you
where these isolator devices are loc-
ated and how to handle them.

2. Open the gas isolator cock fully.
3. Check that the heating installation flow

and return service valves are open, if
such service valves are installed.

4.1.2 Switching on the product

Switch on the product via the main
switch installed on-site.

4.2 Basic display

The operating mode is displayed on the
basic display.
You can switch back to the basic display
by:

Not pressing any button for longer than
5 seconds.

As soon as there is a fault message, the
basic display switches to the fault code.

4.3 Selecting the operating mode

Note

The unit is always activated with
the preselected operating mode.

Summary of Contents for HOME REGULAR 12-A

Page 1: ...or Operating instructions HOME REGULAR GB IE Operating instructions Publisher manufacturer Vaillant GmbH Berghauser Str 40 D 42859 Remscheid Tel 49 21 91 18 0 Fax 49 21 91 18 28 10 info vaillant de ww...

Page 2: ...8 4 2 Basic display 8 4 3 Selecting the operating mode 8 4 4 Setting the hot water temperature 9 4 5 Setting the heating flow temperature 9 4 6 Product settings 9 4 7 Switching the product to standby...

Page 3: ...ng installations and for hot wa ter generation Intended use includes the fol lowing observance of the operating instructions included for the product and any other system components compliance with al...

Page 4: ...etent person 1 3 4 Risk of death from escaping flue gas If you operate the product with an empty condensate siphon flue gas may escape into the room air In order to operate the product ensure that the...

Page 5: ...tion and room air Sprays solvents chlorinated cleaning agents paint adhes ives ammonia compounds dust or similar substances may lead to corrosion on the product and in the air flue pipe Ensure that th...

Page 6: ...at the manufacturer s site 3 2 Information on the identification plate The identification plate is mounted on the underside of the product in the factory The identification plate keeps record of the...

Page 7: ...ode DSN Specific product code CE label section Read the instructions Recycling and disposal section GC no Gas council number 3 3 Design of the product 1 1 Control elements 3 4 Overview of the operator...

Page 8: ...t has two operating levels Operator operating level This provides access to the most important informa tion and setting options that do not re quire any particular prior knowledge Operating level for...

Page 9: ...ed by the control ler with heating mode activated Set the maximum heating flow temper ature on the boiler Page 9 Set the room temperature on the con troller The actual heating flow temperature is set...

Page 10: ...2 Caring for the product Caution Risk of material damage caused by unsuitable clean ing agents Do not use sprays scouring agents detergents solvents or cleaning agents that con tain chlorine Clean the...

Page 11: ...n annual ser vice must be carried out by a competent person approved at the time by the Health and Safety Executive one year after install ation The cost of this annual service is not included in the...

Page 12: ...tored The product is switched off Switch on the product The heating flow temperature is set too low or to the Heating off position and or the hot water temperature is set too low Set the heating flow...

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ...0207 022 0928 Vaillant Service Solutions 0330 100 3461 Spares Technical Enquiries 01773 596615 info vaillant co uk technicalspares groupservice co uk www vaillant co uk These instructions or parts th...

Reviews: