background image

Notes on the documentation 2

0020244342_01 eloSTOR plus Installation and maintenance instructions

5

2

Notes on the documentation

2.1

Observing other applicable documents

You must observe all the operating and installation in-
structions included with the system components.

2.2

Storing documents

Pass these instructions and all other applicable docu-
ments on to the system operator.

2.3

Applicability of the instructions

These instructions apply for the following products only:

Product article number

VEH 10/7 U

0010021147

3

Product description

3.1

Functional elements

A

B

1

2

3

4

1

Heating coil

2

Inner vessel

3

Overheating protection

4

Temperature sensor

A

Hot water outlet

B

Cold water inlet

3.2

Overview of the operator control elements

1

2

3

1

Temperature selector

2

Control light

3

Energy-saving operation

3.3

Information on the identification plate

Information on the
identification plate

Meaning

Serial number

For identification purposes; 7th to 16th
digits = product article number

VEH ...

System component for the domestic hot
water generation

eloSTOR

Product designation

kW

Nominal output

230 V 50 Hz

Voltage

frequency

MPa

Maximum pressure

IP (e.g. X4D)

Degree of protection against water

3.4

Installation location for the identification
plate

1

1

Identification plate

3.5

CE label

The CE label shows that the products comply with the basic
requirements of the applicable directives as stated on the
identification plate.

The declaration of conformity can be viewed at the manufac-
turer's site.

4

Set-up

4.1

Checking the scope of delivery

Check that the scope of delivery is complete and intact.

Quant-
ity

Description

1

Product

1

Documentation records

1

Wall-mounting base

Summary of Contents for eloSTOR plus VEH 10/7 U

Page 1: ...tion and maintenance instructions eloSTOR plus VEH 10 7 U AT DE Publisher manufacturer Vaillant GmbH Berghauser Str 40 D 42859 Remscheid Tel 49 21 91 18 0 Fax 49 21 91 18 2810 info vaillant de www vai...

Page 2: ...uirements 6 5 2 Installing the safety group 7 5 3 Establishing the water connection 7 5 4 Filling the product 7 5 5 Electrical installation 7 6 Start up 8 6 1 Setting the hot water temperature 8 6 2 S...

Page 3: ...a fixed and permanent location known as fixed installation Any other use that is not specified in these instructions or use beyond that specified in this document shall be considered improper use Any...

Page 4: ...ing hot or cold water If you use plastic pipes for the hot or cold water connection of the product you must only use pipes that are temperature res istant up to 95 C under a pressure of 1 0 MPa 10 bar...

Page 5: ...nts 1 2 3 1 Temperature selector 2 Control light 3 Energy saving operation 3 3 Information on the identification plate Information on the identification plate Meaning Serial number For identification...

Page 6: ...ple Do not wall mount the product if you cannot provide wall mounting apparatus with a sufficient load bearing capacity 5 Installation Danger Risk of scalding and or risk of material damage due to inc...

Page 7: ...stop cock 2 Fill the domestic hot water cylinder Always fill the direct electric domestic hot water cyl inder with water before you switch it on The cylinder is full when water escapes as you open the...

Page 8: ...selector knob with the setting ring onto the adjusting spindle 3 6 2 Switching on 1 Ensure that the direct electric domestic hot water cylin der has been filled 2 Insert the mains plug into the wall...

Page 9: ...components that are subject to wear 8 2 Replacing the power supply cable Note To avoid danger if the power supply cable is damaged it must be replaced by the manufac turer their responsible customer s...

Page 10: ...e 9 6 Fill the domestic hot water cylinder 7 Connect the product to the power grid 8 7 Replacing the control and or safety cut out 1 Disconnect the product from the power mains and make sure that it c...

Page 11: ...e 60 Temperature limit possible 40 60 Mixed water volume at 40 C 17 l Maximum operating pressure 0 7 MPa 7 0 bar Product dimensions width 290 mm Product dimensions depth 284 mm Product dimensions heig...

Page 12: ...elefon 05 7050 Telefax 05 7050 1199 Telefon 05 7050 2100 zum Regionaltarif sterreichweit bei Anrufen aus dem Mobilfunknetz ggf abweichende Tarife n here Information erhalten Sie bei Ihrem Mobilnetzbet...

Reviews: