The product consists of a cylindrical heat exchanger with
heating rods and a hydraulic group. The hydraulic group
includes the heating pump, the pressure sensor and the
expansion relief valve. A maintenance valve in the hydraulic
group acts as an automatic air vent. To compensate for
the expansion of the water in the heating system when it is
heated, a 7-litre expansion vessel has been installed.

3.3

Functionality

The product is designed to be operated in domestic hot wa-
ter heating systems with controlled water circulation. The
product can be switched on and off in increments. Unwanted
pulses in the power grid during switching on and off are pre-
vented as the product is not switched on and off until after a
delay of 10-70 seconds (depending on the product's output).

To save energy and reduce mechanical wear, the pump only
works when required. After switching off, the pump continues
to run for approx. one minute in order to make use of the
energy in the water flowing back into the domestic hot water
cylinder/heat exchanger.

The heat supply is guaranteed during the activation times
for the most economical low tariff. If an optional domestic
hot water cylinder is available, the cylinder content is then
heated and is available during the anti-cycling time for heat-
ing the flat.

The product has a steel housing with integrated front plate.
The inlet and outlet for the heating water and the electric
connection are located on the underside of the product.

The product is designed for wall installation. To achieve a
higher output, several products can be combined in a cas-
cade operation and controlled by a single room temperature
control. This is connected to the primary product.

3.4

Pump operating modes

The pump's electronics automatically control the differential
pressure target value.

3.5

Information on the data plate

The data plate is located inside on the base of the casing.

Information on the
data plate

Meaning

Read the instructions.

VE.. /14

Type designation

..6..

Power

EU I

Target market

eloBLOCK

Marketing name

PMS

Permissible total excess pressure in
heating mode

T

max.

(e.g. 85 °C)

Max. flow temperature

V Hz

Mains voltage and mains frequency

IP

IP rating

P

Nominal heat output range

Q

Heat input range

DataMatrix code with serial number,
7th to 16th digit = product article number

3.6

CE marking

The CE marking shows that the products comply with the
basic requirements of the applicable directives as stated on
the data plate.

The declaration of conformity can be viewed at the manufac-
turer's site.

3.7

Serial number

The serial number can be found on the identification plate.

4

Set-up

4.1

Checking the scope of delivery

1.

Remove the product from its box.

2.

Remove the protective film from all parts of the product.

3.

Check that the scope of delivery is complete and intact.

4.1.1

Scope of delivery

Number

Description

1

eloBLOCK

1

Product holder

1

Enclosed documentation

1

Enclosed fastening material:

3 x rawl plug 10 x 60

3 x screw M6 x 60

4.2

Dimensions

310

410

74

0

Summary of Contents for eloBLOCK VE 12 /14 EU I

Page 1: ...allation and maintenance instructions eloBLOCK VE 14 EU I FI fi Publisher manufacturer Vaillant GmbH Berghauser Str 40 D 42859 Remscheid Tel 492191 18 0 Fax 492191 18 2810 info vaillant de www vaillan...

Page 2: ...leak tightness 14 7 Adapting the product to the heating installation 14 8 Handing the product over to the end user 14 9 Troubleshooting 14 9 1 Eliminating faults 14 9 2 Eliminating faults in the pump...

Page 3: ...nance instructions for the product and any other system com ponents installing and setting up the product in ac cordance with the product and system ap proval compliance with all inspection and main t...

Page 4: ...rsons are particularly at risk even at lower temperatures Select a moderate set target temperature Inform the operator about the risk of scald ing when the anti Legionella function is switched on 1 4...

Page 5: ...0010023696 VE 28 14 EU I 0010023697 3 Product description 3 1 Product design 1 2 3 4 5 6 14 13 12 11 10 9 8 7 1 Automatic air vent 2 NTC sensor 3 Contactor 4 Printed circuit board 5 Contactor 6 Power...

Page 6: ...inlet and outlet for the heating water and the electric connection are located on the underside of the product The product is designed for wall installation To achieve a higher output several products...

Page 7: ...3 either 4 5 Wall mounting the product 1 Check whether the wall has sufficient load bearing ca pacity to bear the operational weight of the product 2 Check if the supplied fixing material may be used...

Page 8: ...above illustration 4 7 Installing and removing the side casing 4 7 1 Removing the side casing B A D C Caution Risk of material damage caused by mech anical deformation Removing both side sections may...

Page 9: ...ial damage caused by residues in the pipelines Welding remnants sealing residues dirt or other residues in the pipelines may damage the product Flush the heating installation thoroughly before install...

Page 10: ...par tition with a contact gap of at least 3 mm e g fuses or power switches Page 24 Route a three phase power supply cable that complies with the relevant standards through the grommet and into the pro...

Page 11: ...relay An external load shedding relay can control the product s power depending on the mains load in the building If the mains supply is under an excessive load the product s power automatically decre...

Page 12: ...and technical rules do not stipulate more stringent requirements the following applies You must treat the heating water in the following cases If the entire filling and supplementary water quantity d...

Page 13: ...2 MPa 1 0 2 0 bar is displayed If the heating installation is to supply several storeys a higher filling pressure may be required If the pressure falls short by 0 08 MPa 0 8 bar a pressure sensor sign...

Page 14: ...a fault occurs in the pump this is shown by the pump s status LED Use the table in the appendix to eliminate the fault Pump status LED Page 23 If you are unable to eliminate the fault contact Customer...

Page 15: ...s fixing screw 1 on the underside of the product 6 Carefully turn the pump clockwise so that it can be re moved from the product 7 When you install the new pump use new seals O rings coated with a wa...

Page 16: ...on relief valve and use the safety clip to secure it in place 3 Check that the new expansion relief valve is seated firmly and check it for tightness 10 8 Replace the pressure sensor 2 1 3 1 Remove th...

Page 17: ...e PCB and the display 2 Replace the PCB and the display 3 Plug all of the connection cables into their original slots 4 Check all of the connections using the connection dia gram Page 24 5 Connect the...

Page 18: ...allation and maintenance instructions eloBLOCK 0020265768_01 13 Customer service Validity Finland Vaillant Asiakaspalvelumme yhteystiedot l ytyv t takapuolella mainitun osoitteen alta tai WWW sivulta...

Page 19: ...only be accessed after entering a password In the diagnostics mode you can change various parameters to adapt the product to the heating installation Since the code table is used for various products...

Page 20: ...omestic hot water mode stage 2 2 Automatic heating mode pump prerun overrun stage 1 domestic hot water mode stage 2 3 Always stage 2 4 Automatic heating mode pump prerun overrun stage 1 domestic hot w...

Page 21: ...D 081 Operating hours domestic hot water generation In hours h Not ad justable D 082 Number of heating cycles in heating mode x 100 3 corresponds to 300 Number of heating cycles Not ad justable D 083...

Page 22: ...nics defective F 010 Short circuit Temperature sensor NTC Plug on sensor has a short to earth at the housing Short circuit in the cable harness Sensor defective F 013 Short circuit Cylinder temperatur...

Page 23: ...ature sensor measures 3 C The fault is automatically reset if T C 4 C No fault is displayed if the sensor is defective F 180 Welded relay The fault is displayed if a welded relay has been detected fiv...

Page 24: ...ly main connection block 5 Contactor 1 6 Power supply for external VR 40 module 7 Safety cut out 8 Heating pump 9 Connection for 3 port diverter valve 10 RE 14 relay for heating pump 11 RE 15 3 port d...

Page 25: ...Power supply for external VR 40 module 7 Safety cut out 8 Heating pump 9 Connection for 3 port diverter valve 10 RE 14 relay for heating pump 11 RE 15 3 port diverter valve 12 RE 16 relay for contacto...

Page 26: ...ly for external VR 40 module 7 Safety cut out 8 Heating pump 9 Connection for 3 port diverter valve 10 RE 14 relay for heating pump 11 RE 15 3 port diverter valve 12 RE 16 relay for contactor 13 RE 13...

Page 27: ...if necessary X Check the purging valve the expansion relief valve the 3 way diverter valve the heat exchanger and all of the hydraulic components X Safety test Check all of the sensors thermostats and...

Page 28: ...ristic values of the VRC DCF outdoor temperature sensor Temperature C Resistance ohms 25 2167 20 2067 15 1976 10 1862 5 1745 0 1619 5 1494 10 1387 15 1246 20 1128 25 1020 30 920 35 831 40 740 K Charac...

Page 29: ...8 l 8 l 8 l Flow return heating connections G 3 4 G 3 4 G 3 4 G 3 4 Boiler dimension width 410 mm 410 mm 410 mm 410 mm Boiler dimension height 740 mm 740 mm 740 mm 740 mm Unit dimensions depth 315 mm...

Page 30: ...10 K 1 548 l h 1 806 l h 2 064 l h 2 408 l h Pump remaining feed head at T 10 K 24 kPa 240 mbar 20 kPa 200 mbar 16 5 kPa 165 0 mbar 11 kPa 110 mbar Number of immersion heaters pcs x kW 3 x 6 3 x 7 4 x...

Page 31: ...ont casing 8 Frost 4 H Handing the product over to the end user 14 Hot water temperature Risk of scalding 4 I Inspection work 14 27 Installation site 4 Intended use 3 M Maintenance 14 Maintenance work...

Page 32: ...Berghauser Strasse 40 42859 Remscheid Tel 492191 18 0 www vaillant info These instructions or parts thereof are protected by copyright and may be reproduced or distributed only with the manufacturer...

Reviews: